Datalogic QLM500 Installation Manual

Browse online or download Installation Manual for Bar code readers Datalogic QLM500. Datalogic QLM500 Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 119
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - REFERENCE MANUAL

REFERENCE MANUAL > DS2400N Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Page 2

x GENERAL VIEW DS2400N Figure A 4 5 7 8 3 6 9 10 11 2 1 1 Warning and Device Class Labels 2 3 4 5 6 &quo

Page 3 - CONTENTS

DS2400N REFERENCE MANUAL 88 7 7.2 LINEAR CODE READING The number of scans performed on the code by the DS2400N and therefore the decoding cap

Page 4

READING FEATURES 89 7 7.2.2 Picket-Fence Mode If scanning is parallel to the code motion, (Figure 106), the number of effective scans is given by the

Page 5 - REFERENCES

DS2400N REFERENCE MANUAL 90 7 7.3 PERFORMANCE The DS2400N scanner is available in different versions according to the reading performa

Page 6 - LASER SAFETY

READING FEATURES 91 7 7.4 READING DIAGRAMS Reading diagrams for Subzero models and Standard models are the same. DS2400N-020X (Short Reading Ra

Page 7 - POWER SUPPLY

DS2400N REFERENCE MANUAL 92 7 DS2400N-120X (Medium Reading Range) Note: (0,0) is the center of the laser beam output window. CONDITIONS Optic

Page 8 - HANDLING

READING FEATURES 93 7 DS2400N-220X (Long Reading Range) Note: (0,0) is the center of the laser beam output window. CONDITIONS Optic Version =

Page 9

DS2400N REFERENCE MANUAL 94 8 8 MAINTENANCE 8.1 CLEANING Clean the laser beam output window periodically for continued correct operation

Page 10 - GENERAL VIEW

TROUBLESHOOTING 95 9 9 TROUBLESHOOTING 9.1 GENERAL GUIDELINES When wiring the device, pay careful attention to the signal name (acro

Page 11 - DS2400N Subzero

DS2400N REFERENCE MANUAL 96 9 TROUBLESHOOTING GUIDE Problem Suggestions Power On: the "Power On"/ "Ready" LED are not lit Is po

Page 12

TROUBLESHOOTING 97 9 TROUBLESHOOTING GUIDE Problem Suggestions Reading: Not possible to read the target barcode (always returns No Read) or the Auto

Page 13 - 1 RAPID CONFIGURATION

xi DS2400N Subzero Figure A 2 1 4 5 7 9 3 6 10 11 8 1 Warning and Device Class Labels 2 3 4 5 6 "POWER ON

Page 14

DS2400N REFERENCE MANUAL 98 10 10 TECHNICAL FEATURES ELECTRICAL FEATURES DS2400N-xxx0 (Standard) DS2400N-xxx5 (Subzero) Input Power Supply Volt

Page 15 - RAPID CONFIGURATION

TECHNICAL FEATURES 99 10 ENVIRONMENTAL FEATURES DS2400N-xxx0 (Standard) DS2400N-xxx5 (Subzero) Operating Temperature 0° to +45 C (+32° to +113 °F)

Page 16

100 GLOSSARY ACR-Lite (Advanced Code Reconstruction) This is a light version of the powerful Advanced Code Reconstruction technology applied to high p

Page 17

101 Full Duplex Simultaneous, two-way, independent transmission in both directions. Half Duplex Transmission in either direction, but not simultaneous

Page 18 - Auto Learn

102 RS232 Interface between data terminal equipment and data communication equipment employing serial binary data interchange. RS485 Interfac

Page 19 - Auto Setup (Optional)

103 INDEX 2 25-Pin Cable Electrical Connections, 55 A Accessories, 24 Advanced Code Reconstruction (ACR-Lite), 84 Auxiliary RS232 Interface, 48, 66 C

Page 20

DECLARATION OF CONFORMITY EC-031Rev.: 4 Pag.: 1 di 1 Datalogic Automation S.r.l. Via Lavino 265 40050 Monte San Pietro Bologna - Italydeclares

Page 21

DECLARATION OF CONFORMITY EC-016Rev.: 4 Pag.: 1 di 1 Datalogic Automation S.r.l. Via Lavino 265 40050 Monte San Pietro Bologna - Italydeclares

Page 22

DECLARATION OF CONFORMITY EC-127Rev.: 1 Pag.: 1 di 1 Datalogic Automation S.r.l. Via Lavino 265 40050 Monte San Pietro Bologna - Italydeclares

Page 23

DECLARATION OF CONFORMITY EC-128Rev.: 2 Pag.: 1 di 1 Datalogic Automation S.r.l. Via Lavino 265 40050 Monte San Pietro Bologna - Italydeclares

Page 24

xii Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]

Page 25 - STEP 5 – TEST MODE

RAPID CONFIGURATION 1 1 1 RAPID CONFIGURATION NOTE This chapter illustrates a Stand Alone application. For other types of installation

Page 26 - Alternative Layouts

DS2400N REFERENCE MANUAL 2 1 CBX100/500 Pinout for DS2400N The table below gives the pinout of the CBX100/500 terminal block connectors

Page 27 - 2 INTRODUCTION

RAPID CONFIGURATION 3 1 25-pin Connector Pinout for DS2400N The table below gives the pinout of the 25-pin male D-sub connector for connection to

Page 28 - 2.2 ID-NET™

DS2400N REFERENCE MANUAL 4 1 STEP 2 – MOUNTING AND POSITIONING THE SYSTEM 1. To mount the DS2400N, use the mounting bracket to obtain the most su

Page 29 - INTRODUCTION

RAPID CONFIGURATION 5 1 STEP 3 – X-PRESS™ CONFIGURATION X-PRESS™ is the intuitive Human Machine Interface designed to improve ease of in

Page 30

DS2400N REFERENCE MANUAL 6 1 Auto Learn If you are configuring your scanner using X-PRESS™, you must start with the Auto Learn procedure.

Page 31 - 2.3.1 Diagnostic Indication

RAPID CONFIGURATION 7 1 Auto Setup (Optional) At the end of the Auto Learn procedure, you have the possibility to follow the Auto Se

Page 32 - Test Mode Function

Datalogic Automation Srl Via Lavino, 265 40050 - Monte S. Pietro Bologna - Italy DS2400N Reference Manual Ed.: 11/2013 © 2007 – 2013 Datalogic Au

Page 33 - AutoSetup Function

DS2400N REFERENCE MANUAL 8 1 STEP 4 – INSTALLING GENIUS™ CONFIGURATION PROGRAM Genius™ is a Datalogic scanner configuration tool providing several

Page 34 - Internal Temperature (°C)

RAPID CONFIGURATION 9 1 1. Select the Create a new configuration button. You will be guided through the configuration being asked to

Page 35 - 2.5 MODEL DESCRIPTION

DS2400N REFERENCE MANUAL 10 1 b. Operating mode selection and definition c. Digital Outputs configuration Phone: 800.894.0412 - Fax: 888.

Page 36 - 2.6 ACCESSORIES

RAPID CONFIGURATION 11 1 d. Hardware interface selection e. Output data format configuration The On Line operating Mode requires t

Page 37 - 3 INSTALLATION

DS2400N REFERENCE MANUAL 12 1 2. After defining the parameter values the following window appears allowing to complete the reader configur

Page 38 - 3.2 MECHANICAL INSTALLATION

RAPID CONFIGURATION 13 1 STEP 5 – TEST MODE Use a code suitable to your application to test the system. Alternatively, you can use the

Page 39 - 3.2.1 Mounting DS2400N

DS2400N REFERENCE MANUAL 14 1 ADVANCED SCANNER CONFIGURATION The ADVANCED selection available when starting the Genius™ program is addre

Page 40 - Cover Screws

INTRODUCTION 15 2 2 INTRODUCTION 2.1 PRODUCT DESCRIPTION The DS2400N laser scanner satisfies the most advanced needs of a wide range of users.

Page 41

DS2400N REFERENCE MANUAL 16 2 2.1.1 Indicators The five LEDs on the side of the scanner (Figure A) indicate the following: READY (green) This LE

Page 42

INTRODUCTION 17 2  ID-NET™ M/S Multidata: Multiple stations – single scanner ID-NET™ interface allows connection of scanners reading obj

Page 43 - INSTALLATION

NOME MANUALE/NOME CAPITOLO iii 1 CONTENTS REFERENCES ...

Page 44

DS2400N REFERENCE MANUAL 18 2 2.2.1 How To Setup/Configure the Scanner Network A complete ID-NET™ scanner network can be rapidly setup, as follow

Page 45

INTRODUCTION 19 2 2.3 X-PRESS™ HUMAN MACHINE INTERFACE X-PRESS™ is the intuitive Human Machine Interface designed with the precise goal

Page 46

DS2400N REFERENCE MANUAL 20 2 2.3.2 X-PRESS™ Functions Quick access to the following functions is provided by an easy procedure using the push bu

Page 47

INTRODUCTION 21 2 AutoLearn Function Once entered, the reader starts a procedure to automatically detect and recognize barcodes (by type and len

Page 48 - 3.3 POSITIONING

DS2400N REFERENCE MANUAL 22 2 Reset Scanner to Factory Default If it ever becomes necessary to reset the scanner to the factory defaul

Page 49 - CBX ELECTRICAL CONNECTIONS

INTRODUCTION 23 2 2.5 MODEL DESCRIPTION The DS2400N scanner is available in versions that differ in regard to the following parameter

Page 50 - 4.2 MAIN SERIAL INTERFACE

DS2400N REFERENCE MANUAL 24 2 2.6 ACCESSORIES The following accessories are available on request for the DS2400N: Name Description Part Number M

Page 51 - 4.2.1 RS232 Interface

INSTALLATION 25 3 3 INSTALLATION 3.1 PACKAGE CONTENTS Verify that the DS2400N reader and all the parts supplied with the equipment a

Page 52

DS2400N REFERENCE MANUAL 26 3 3.2 MECHANICAL INSTALLATION DS2400N can be installed to operate in different positions. The four screw holes (M4 x

Page 53

INSTALLATION 27 3 3.2.1 Mounting DS2400N Using the DS2400N mounting bracket you can obtain the most suitable position for the reader

Page 54 - Multidrop Cable

iv 4.3.1 ID-NET™ Cables ... 43 4.3.2 ID-NET™ Resp

Page 55 - 4.3.1 ID-NET™ Cables

DS2400N REFERENCE MANUAL 28 3 3.2.2 Mounting a GFC-2020 Accessory Lateral Output Deflection Mirror The GFC-2020 accessory is a Lateral Outp

Page 56 - Number of Nodes

INSTALLATION 29 3 3.2.3 Mounting a GFC-2100 Accessory Lateral Output Deflection Mirror The GFC-2100 accessory is a 90° Lateral Output deflection m

Page 57

DS2400N REFERENCE MANUAL 30 3 3.2.4 Mounting a GFC-200 Accessory Contact Reading Mirror The GFC-200 is an 85° contact reading mirror that

Page 58

INSTALLATION 31 3 To fix a DS2400N Scanner to the GFC-200, use the two M 4 x 6 mm screws supplied with the GFC Kit. Refer to the following figure.

Page 59

DS2400N REFERENCE MANUAL 32 3 The internal optical path from the scanner reading window to the GFC-200 window is 51 mm. The reading

Page 60

INSTALLATION 33 3 3.2.5 Mounting an OM2000N Accessory Oscillating Mirror The OM2000N oscillating mirror is designed to generate homogeneous and ad

Page 61 - PH-1 Photocell (PNP)

DS2400N REFERENCE MANUAL 34 3 The installation of the deflection mirror is very easy. 1) Clean the OM2000N mirror surface and output window (inte

Page 62

INSTALLATION 35 3 The reading distance of the scanner with the OM2000N is shifted by 10 mm towards the scanner because of the interna

Page 63

DS2400N REFERENCE MANUAL 36 3 3.3 POSITIONING The DS2400N scanner is able to decode moving barcode labels at a variety of angles, h

Page 64 - 4.6 OUTPUTS

CBX ELECTRICAL CONNECTIONS 37 4 4 CBX ELECTRICAL CONNECTIONS All DS2400N models are equipped with a cable terminated by a 25-pin male D-sub conne

Page 65

v REFERENCES CONVENTIONS This manual uses the following conventions: “User” or “Operator” refers to anyone using a DS2400N. “Device” refers to the DS2

Page 66

DS2400N REFERENCE MANUAL 38 4 NOTE To avoid electromagnetic interference when the scanner is connected to a CBX connection box, verify the jumper

Page 67 - (SW SELECTABLE)

CBX ELECTRICAL CONNECTIONS 39 4 4.2.1 RS232 Interface The serial interface is used in this case for point-to-point connections; it han

Page 68

DS2400N REFERENCE MANUAL 40 4 4.2.2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-pol

Page 69 - USER INTERFACE

CBX ELECTRICAL CONNECTIONS 41 4 4.2.3 RS485 Half-Duplex Interface NOTE This interface is provided for backward compatibility. We recommend using

Page 70

DS2400N REFERENCE MANUAL 42 4 Figure 44 - DS2400N Multidrop Connection to a Multiplexer * When using CBX500, the Main interface multidrop

Page 71 - MULTIPLEXER

CBX ELECTRICAL CONNECTIONS 43 4 4.3 ID-NET™ INTERFACE CBX100/500 Function Shield Network Cable Shield ID+ ID-NET™ network + ID- ID-NET™ network -

Page 72

DS2400N REFERENCE MANUAL 44 4 4.3.2 ID-NET™ Response Time The following figure shows the response time of the ID-NET™ network. This time is defin

Page 73 - 5.3.1 ID-NET™ Cables

CBX ELECTRICAL CONNECTIONS 45 4 Figure 46 – ID-NET™ Network Connections with isolated power blocks Phone: 800.894.0412 - Fax: 888.723.4773 - We

Page 74

DS2400N REFERENCE MANUAL 46 4 Figure 47 - ID-NET™ Network Connections with Common Power Branch Network Phone: 800.894.0412 - Fax: 888.723.477

Page 75

CBX ELECTRICAL CONNECTIONS 47 4 Figure 48 – ID-NET™ Network Connections with Common Power Star Network Phone: 800.894.0412 - Fax: 888.723.4773 - We

Page 76

vi SAFETY AND COMPLIANCE NOTICES CAUTION Subzero model scanners must not be opened in an uncontrolled environment. LASER SAFETY The

Page 77

DS2400N REFERENCE MANUAL 48 4 4.3.3 ID-NET™ Network Termination The network must be properly terminated in the first and last scanner of the netw

Page 78

CBX ELECTRICAL CONNECTIONS 49 4 4.5 INPUTS There are two optocoupled polarity insensitive inputs available on the scanner: Input 1 (Ex

Page 79 - 5.5 INPUTS

DS2400N REFERENCE MANUAL 50 4 Power to Input Photocell Signal Photocell Reference NPN Photocell Figure 52 - NPN External Trigger Using DS24

Page 80

CBX ELECTRICAL CONNECTIONS 51 4 CBX100/500 Function +V Power Source - Inputs I2A Input 2 A (polarity insensitive) I2B Input 2 B (polarity insensitiv

Page 81 - Vext 30 Vdc max

DS2400N REFERENCE MANUAL 52 4 Pulled up to External Input Device Power Input Signal Input Device Figure 56 - NPN Input 2 Using External Power 4

Page 82 - 5.6 OUTPUTS

CBX ELECTRICAL CONNECTIONS 53 4 OUTPUT CONNECTIONS USING DS2400N POWER Power to Output Output device Signal Output device Reference Output Device Fi

Page 83 - 5.7 USER INTERFACE - HOST

DS2400N REFERENCE MANUAL 54 4 4.7 USER INTERFACE - HOST The following table contains the pinout for standard RS232 PC Host interface. For other u

Page 84 - 6 TYPICAL LAYOUTS

25-PIN CABLE ELECTRICAL CONNECTIONS 55 5 5 25-PIN CABLE ELECTRICAL CONNECTIONS All DS2400N models are equipped with a cable terminated by a 25-pi

Page 85

DS2400N REFERENCE MANUAL 56 5 5.1 POWER SUPPLY Power can be supplied to the scanner through the pins provided on the 25-pin connect

Page 86 - 6.2 PASS-THROUGH

25-PIN CABLE ELECTRICAL CONNECTIONS 57 5 5.2.1 RS232 Interface The serial interface is used in this case for point-to-point connections;

Page 87

vii Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light. The la

Page 88 - 6.3 ID-NET™

DS2400N REFERENCE MANUAL 58 5 5.2.2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-pol

Page 89

25-PIN CABLE ELECTRICAL CONNECTIONS 59 5 5.2.3 RS485 Half-Duplex Interface NOTE This interface is provided for backward compatibility. We recomme

Page 90 - ID-NET™

DS2400N REFERENCE MANUAL 60 5 Figure 68 - DS2400N Multidrop Connection to a Multiplexer Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiaut

Page 91

25-PIN CABLE ELECTRICAL CONNECTIONS 61 5 5.3 ID-NET™ INTERFACE 25-pin Name Function 23 ID+ ID-NET™ network + 24 ID- ID-NET™ network - 7 GND Ground

Page 92

DS2400N REFERENCE MANUAL 62 5 5.3.2 ID-NET™ Response Time The following figure shows the response time of the ID-NET™ network. This time is defined a

Page 93 - INTERFACE

25-PIN CABLE ELECTRICAL CONNECTIONS 63 5 Figure 70 – ID-NET™ Network Connections with isolated power blocks Phone: 800.894.0412 - Fax: 888.723.

Page 94 - 6.4 RS232 MASTER/SLAVE

DS2400N REFERENCE MANUAL 64 5 Figure 71 - ID-NET™ Network Connections with Common Power Branch Network Phone: 800.894.0412 - Fax: 888.723.477

Page 95 - 6.5 MULTIPLEXER LAYOUT

25-PIN CABLE ELECTRICAL CONNECTIONS 65 5 Figure 72 – ID-NET™ Network Connections with Common Power Star Network Phone: 800.894.0412 - Fax: 888.723.

Page 96 - 7 READING FEATURES

DS2400N REFERENCE MANUAL 66 5 5.3.3 ID-NET™ Network Termination The network must be properly terminated by a 120 Ohm resistor at the first and la

Page 97

25-PIN CABLE ELECTRICAL CONNECTIONS 67 5 5.5 INPUTS There are two optocoupled polarity insensitive inputs available on the scanner: Inp

Page 98 - Laser Beam

viii CE COMPLIANCE Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which

Page 99

DS2400N REFERENCE MANUAL 68 5 EXTERNAL TRIGGER INPUT CONNECTIONS USING DS2400N POWER EXTERNAL TRIGGER DS2400N 18 19 9 7 Ground V Signal VCC ~ ~ +

Page 100 - 7.2.1 Step-Ladder Mode

25-PIN CABLE ELECTRICAL CONNECTIONS 69 5 25-pin Name Function 9 Vdc Power Source Inputs 6 I2A Input 2 A (polarity insensitive) 10 I2B Input 2 B (pol

Page 101 - 7.2.2 Picket-Fence Mode

DS2400N REFERENCE MANUAL 70 5 5.5.1 Code Verifier If the DS2400N is used as a Code Verifier, the verifier code can be configured in software through

Page 102 - 7.3.1 Raster

25-PIN CABLE ELECTRICAL CONNECTIONS 71 5 USER INTERFACE O+ 8/11 22/12 O- DS2400N Vext 30 Vdc max. C E Figure 84 - Open Collector Output Connectio

Page 103 - 7.4 READING DIAGRAMS

DS2400N REFERENCE MANUAL 72 6 6 TYPICAL LAYOUTS The following typical layouts refer to system hardware configurations. Dotted lines i

Page 104 - DS2400N REFERENCE MANUAL

TYPICAL LAYOUTS 73 6 In this layout a single scanner functions as a Slave node on a Fieldbus network. The data is transmitted to the Host throug

Page 105 - READING FEATURES

DS2400N REFERENCE MANUAL 74 6 6.2 PASS-THROUGH Pass-through mode allows two or more devices to be connected to a single external serial interfa

Page 106 - 8 MAINTENANCE

TYPICAL LAYOUTS 75 6 An alternative Pass-Through layout allows the more efficient ID-NET™ network to be used. This layout is really an ID-NET

Page 107 - 9 TROUBLESHOOTING

DS2400N REFERENCE MANUAL 76 6 6.3 ID-NET™ The ID-NET™ connection is used to collect data from several scanners to build a multi-point or a mult

Page 108

TYPICAL LAYOUTS 77 6 For a Master/Slave Multidata layout each scanner has its own reading phase independent from the others; each single mes

Page 109 - TROUBLESHOOTING

ix do not fine tune the positioning by striking the scanner or bracket. do not weld the scanner into position which can cause el

Page 110 - 10 TECHNICAL FEATURES

DS2400N REFERENCE MANUAL 78 6 Figure 91 – ID-NET™ M/S Synchronized Layout DS2400N Master with CBX500 + DS2400N Slaves with QL100 Figur

Page 111 - TECHNICAL FEATURES

TYPICAL LAYOUTS 79 6 The Master scanner can communicate to the Host as a Slave node on an Ethernet TCP/IP network. This example requires using

Page 112 - GLOSSARY

DS2400N REFERENCE MANUAL 80 6 Alternatively, the Master scanner can communicate to the Host as a Slave node on a Fieldbus network. Th

Page 113

TYPICAL LAYOUTS 81 6 The QLM600 Profibus Gateway active connection module can also be used. System configuration can be accomplished

Page 114

DS2400N REFERENCE MANUAL 82 6 6.4 RS232 MASTER/SLAVE NOTE This interface is provided for backward compatibility. We recommend using the more eff

Page 115

TYPICAL LAYOUTS 83 6 6.5 MULTIPLEXER LAYOUT NOTE This interface is provided for backward compatibility. We recommend using the more efficient ID-

Page 116 - DECLARATION OF CONFORMITY

DS2400N REFERENCE MANUAL 84 7 7 READING FEATURES 7.1 ADVANCED CODE RECONSTRUCTION (ACR-LITE) The traditional way of barcode reading could

Page 117

READING FEATURES 85 7 ACR-Lite is disabled by default but can be enabled for the following code types: Code 25 Interleaved Code 128/GS1-128 C

Page 118

DS2400N REFERENCE MANUAL 86 7 The decoder will be able to read the label with a tilt angle between + max and - max as shown in th

Page 119

READING FEATURES 87 7 7.1.3 Advanced Code Reconstruction Reading Conditions The following tables describe the minimum code height requirements (

Comments to this Manuals

No comments