TYPICAL LAYOUTS
77
6
For a Master/Slave Multidata layout each scanner has its own reading phase independent
from the others; each single message is sent from the master scanner to the Host computer.
Figure 90 ID-NET™ M/S Multidata
The auxiliary serial interface of the slave scanners can be used in Local
Echo communication mode to control any single scanner (visualize
collected data) or to configure it using the Genius™ utility or the Genius™
based Host Mode programming procedure.
The ID-NET™ termination resistor switches must be set to ON only in the first
and last CBX connection box.
Terminal
Main Serial Interface (RS232 or RS485)
Auxiliary Serial Interface (Local Echo) (RS232)
External Trigger (for On-Line Mode)
ID-NET™ (up to 32 devices, max network extension of 1000 m)
Host
1
4
3
2
Master
Slave#1
Slave#n
Power