INSTALLATION
33
3
3.2.5 Mounting an OM2000N Accessory Oscillating Mirror
The OM2000N oscillating mirror is designed to generate homogeneous and adjustable raster
reading through deflection of the scanning laser beam.
The system consists of the oscillating mirror attached to the scanner and allows a surface
instead of a line to be observed; versatility and reading accuracy are therefore increased in
"Picket Fence" reading mode.
The electronic and electromechanical components controlling the mirror movement are
contained inside the rugged metal casing, which guarantees protection class IP65 when the
OM2000N is mounted correctly onto the scanner.
The OM2000N is directly powered from the scanner through a connector which is accessible
after removing the scanning window (see Figure 30). It therefore operates exclusively at low
power, between 10 and 30 VDC.
The OM2000N accessory is not compatible with and therefore cannot be
used on Subzero models.
The following figure gives the overall dimensions of the DS2400N + OM2000N and may be
used for its installation in the application.
Figure 28 – DS2400N + OM2000N Overall Dimensions
107
[4.21]
51.2
[2.02]
32.7
[1.29]
69
[2.72]
44
[1.73]