Datalogic QLM500 Instruction Manual Page 154

  • Download
  • Add to my manuals
  • Print
  • Page
    / 161
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 153
MATRIX 410™ REFERENCE MANUAL
144
11
11 TECHNICAL FEATURES
ELECTRICAL FEATURES
Power
all models except 655-0x0
655-0x0 models
Supply Voltage
10 to 30 Vdc
24 Vdc ± 10%
Consumption
0.8 to 0.27 A, 8 W max.;
0.5 to 0.17 A, 5 W typical
0.4 A + 0.35 A, 18 W max.
Communication Interfaces
Main
- RS232
- RS485 full-duplex
- RS485 half-duplex
2400 to 115200 bit/s
2400 to 115200 bit/s
2400 to 115200 bit/s
Auxiliary - RS232
2400 to 115200 bit/s
ID-NET™
Up to 1MBaud
Ethernet (Ethernet Models only)
10/100 Mbit/s
Inputs
Input 1(External Trigger) and Input 2
Opto-coupled and polarity insensitive
Max. Voltage
30 Vdc
Max. Input Current
10 mA
Outputs
Output 1 and Output 2
Opto-coupled
VOut (ILoad = 0 mA) Max.
30 Vdc
VOut (ILoad = 10 mA) Max.
1.8 Vdc
PD = VOut ILoad Max.
170 mW
OPTICAL FEATURES
4xx-0x0 models
6xx-0x0 models
Image Sensor
CMOS
CCD
Image Format
SXGA (1280x1024)
UXGA (1600x1200)
Frame Rate
27 frames/sec.
15 frames/sec.
Pitch
35°
Tilt
0° - 360°
LED Safety
to EN 62471
all models except 655-0x0
655-0x0 models
Lens
LNS (accessories)
LNS-1135 (35 mm)
Lighting System
Internal or External Illuminator
(accessories)
Ultra High Power Illuminator
ENVIRONMENTAL FEATURES
Operating Temperature
0 to 50 C (32 to 122 °F) *
Storage Temperature
-20 to 70 C (-4 to 158 °F)
Max. Humidity
90% non condensing
Vibration Resistance
14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
EN 60068-2-6
2 g @ 70 to 200 Hz; 2 hours on each axis
Bump Resistance
30g; 6 ms;
EN 60068-2-29
5000 shocks on each axis
Shock Resistance
30g; 11 ms;
EN 60068-2-27
3 shocks on each axis
Protection Class
EN 60529
IP67 **
PHYSICAL FEATURES
all models except 655-0x0
655-0x0 models
Dimensions (with lens cover)
125 x 65 x 87 mm
(4.9 x 2.6 x 3.4 in.)
143 x 100 x 87 mm
(5.6 x 3.9 x 3.4 in.)
Weight (with lens and internal illuminator)
482 g. (17 oz.)
740 g. (26 oz.)
Material
Aluminium
* high ambient temperature applications should use metal mounting bracket for heat dissipation