INTRODUCTION
25
2
2.2 INDICATORS AND KEYPAD BUTTON
Figure 20 - Indicators
The following LED indicators are located on the reader:
NET
yellow LED indicates connection to the on-board Ethernet network (for Ethernet
models) (Figure 20, 1)
PWR
blue LED indicates that the reader is connected to the power supply (Figure 20, 2)
In normal operating mode the colors and meaning of the five LEDs are illustrated in the
following table:
READY
green LED indicates that the reader is ready to operate (Figure 20, 3)
GOOD
green LED confirms successful reading (Figure 20, 4)
TRIGGER
yellow LED indicates the status of the reading phase (Figure 20, 5)
COM
yellow LED indicates active communication on the main serial port * (Figure 20, 6)
STATUS
red LED indicates a NO READ result (Figure 20, 7)
* When connected to a Fieldbus network through the CBX500, the COM LED is always active, even in the
absence of data transmission, because of polling activity on the Fieldbus network.
During the reader startup (reset or restart phase), these five LEDs blink for one second.
In X-PRESS™ Configuration mode the colors and meaning of these five LEDs are described
in par. 2.4.
The keypad button (Figure 20, 8), is software programmable. By default it starts the X-
PRESS™ interface for quick installation without using a PC (see chp. 1).