Datalogic QLM500 Instruction Manual Page 125

  • Download
  • Add to my manuals
  • Print
  • Page
    / 161
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 124
READING FEATURES
115
7
Example:
A Matrix 410™ 600-010 using:
Internal Lighting Mode = Very High Power Strobe
Exposure Time (x10 s) = 10 (100 s)
Code Resolution (X) = 0.254 mm (10 mils)
has a maximum line speed of:
0.254 (mm) / 0.0001 (s) = 2540 mm/s
Likewise, T
exp
(max)
is the maximum Exposure Time value that can be used without blurring
for the given application line speed and code resolution. Therefore:
X / LS
(max)
= T
exp
(max)
T
exp
(max)
and LS
(max)
are represented in the graph below as the curved line for X (code
resolution). Values above the curve result in blurring. In practice, the application values are
somewhere below the theoretical line, (in the green area), due to environmental and other
conditions.
Line Speed
T
exp
SW Limit
T
exp (min)
SW/HW Limit
X
2X
Conveyor Speed
Limit
Readable
Blurring
For example, the maximum target speed in the application is also affected by these
conditions:
Code/Background Contrast: maximum speed decreases when decreasing image
contrast (poor quality codes, reflective transparent coverings, different supports and
printing techniques).
Code Resolution: maximum speed increases when decreasing code resolution, (i.e. 2X).
There is a decrement of overlapping effects between two adjacent elements.
Tilt Angle: maximum speed decreases when increasing Tilt angle (from 0 to 45
degrees).