MATRIX 410™ REFERENCE MANUAL
26
2
2.3 ID-NET™
The ID-NET™ network is a built-in high-speed interface dedicated
for high-speed reader interconnection. ID-NET™ is in addition to
the Main and Auxiliary serial interfaces.
The following network configurations are available:
ID-NET™ M/S Synchronized: Single station multiple readers
ID-NET™ interface allows local connection of multiple readers reading different sides of the
same target. All readers share a single presence sensor and activate/deactivate
simultaneously.
At the end of each reading phase a single data message is transmitted to the host.
Thanks to ID-NET™, data communication among readers is highly efficient so that an
immediate result will be available.