Page view 316
Wireless Features
Product Reference Guide
307
7. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
Changing the pin code setting will unlink the devices. If the Automatic
Configuration Update is set to the default enabled setting, the devices
must only be relinked. If the Automatic Configuration Update is set to the
disabled setting, the Pin Code setting must also be updated in the Base
Station using Aladdin. After the Base Station has been updated, the
devices must be relinked.
Table 51. Bluetooth Pin Code Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
D254 STOR12345678135M
2
Convert the characters
to hexadecimal
44 32 35 34 53 54 4F 52 31 32 33 34 35 36 37 38 31 33 35 4D
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SET Bluetooth PIN CODE
5
Scan 8 or 32
Alphanumeric
Charac
ters From
Appendix D, Keypad
44323534 53544F5231323334353637383133354D
6 Scan ENTER/EXIT PROGRAMMING MODE