Page view 106
Enter/Exit Programming Mode
Product Reference Guide
97
ADD-ONS
Contact Customer Support for advanced programming of optional and con-
ditional add-ons.
Optional Add-ons
The reader can be enabled to optionally read the following add-ons (sup-
plementals):
DEFAULT
$CADO200(CR)
Optional Add-Ons = Disable P2
$CADO201(CR)
Optional Add-Ons = Enable P2
DEFAULT
$CADO500(CR)
Optional Add-Ons = Disable P5
$CADO501(CR)
Optional Add-Ons = Enable P5
DEFAULT
$CADO800(CR)
Optional Add-Ons = Disable GS1-128
$CADO801(CR)
Optional Add-Ons = Enable GS1-128
If a UPC/EAN base label and an add-on are both decoded, the reader
will transmit the base label and add-on. If a UPC/EAN base label is
decoded without an add-on, the base label will be transmitted without
an add-on.
Conditional add-on settings (if enabled) are considered by the reader
before optional add-on settings.