BHS AND REDS INSTALLATION MANUAL
56
6
Parameter
Values (default)
Function
Check Encoder Failure
Enabled/Disabled
Encoder diagnostics affects the
switch over
Encoder Failure Event
Filter
1-10; (5)
Number of times the alarm must be
repeated before the switch over
occurs
Check Max Consecutive
Lost Parcels
Enabled/Disabled
Max Consecutive Lost Parcels
affects the switch over
Max Consecutive Lost
Parcels
2-20; (5)
Number of Lost parcels recognized
by the Standby controller before the
switch over occurs
Check Max % Of Lost
Parcels (Out Of 100
Parcels)
Enabled/Disabled
Max % Of Lost Parcels affects the
switch over
Max % Of Lost Parcels
(Out Of 100 Parcels)
2-100; (15)
Percentage (number) of Lost
parcels recognized by the Standby
controller before the switch over
occurs
Data Communication
Settings
\Built-in
Ethernet\LineParameters
IP-address Active *
IP address
Active SC6000
IP-address Standby *
IP address
Standby SC6000
Data Communication
Settings
\Additional
Ethernet\LineParameters
Only Dual Ethernet Models
IP-address Active *
IP address
Active SC6000
IP-address Standby *
IP address
Standby SC6000
Digital I/O Setting\Digital
Output Lines
Setting\Output 6
Use
Local/Built-in
EthernetIP/ Built-in
Profinet/Additional
EthernetIP/ Additional
Profinet/Profibus/Redun
dancy
Usage of OUT6: if set to
Redundancy, this digital output is
used to indicate the Active/Standby
status
Diagnostics
\Redundancy Diagnostic
Notification
Enable on Master Active
Enabled/Disabled
Enable/Disable transmission of
REDS diagnostic on the Active
Master
Enable on Master Standby
Enabled/Disabled
Enable/Disable transmission of
REDS diagnostic on the Standby
Master