Datalogic Controller SC6000 Installation Manual Page 57

  • Download
  • Add to my manuals
  • Print
  • Page
    / 78
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 56
REDUNDANT SYSTEMS
51
6
Role Conflicts
A role conflict may occur under various circumstances. In the event of a role conflict an
automatic negotiation will lead to the automatic correction of the configuration and definition
of the correct roles.
Configuration
If compared with a stand-alone station, no additional settings are needed on the slave
scanners when the REDS function is used. All the parameters related to REDS function have
to be set on the active SC6000 as described in par. 6.4.1. Once this is done, a simple
procedure is needed to align the reserve SC6000 (see par. 6.4.2).
Topology Parameters
Two important configuration parameters are defined in the SC6000s to manage a Redundant
System:
TOPOLOGY REDUNDANCY ROLE
(values: Working/Protecting): this parameter is operator assigned and strictly connected to
the Lonworks address of the controller (0: Working, 63: Protecting). It represents the role
statically assigned to a controller: “Working” for the main controller and “Protecting” for the
reserve controller.
REDUNDANCY ROLE
(values: Active/Standby): this parameter is read-only and represents the role that the
controller dynamically plays in the redundant system at a certain moment.
When TOPOLOGY REDUNDANCY ROLE is set to Working”, REDUNDANCY ROLE is set to
“Active” by default.
When TOPOLOGY REDUNDANCY ROLE is set to “Protecting”, REDUNDANCY ROLE is set to
“Standby” by default.
IP Addresses
The companion controllers have different IP address values and the parameter tree of each
controller contains the IP addresses of both of them. In order to manage the interface to any
external host computer (WebSentinel PC, Genius PC or generic host) when a switch over
occurs, two separate policies have been defined to select the IP address when switching
over:
if the parameter IP Address Selection Rule is set to Topology Role (W/P), the IP address
seen by the external host changes after switching over (the topology role is static).
if the parameter IP Address Selection Rule is set to Redundancy Role (A/S), the IP
address seen by the external host remains unchanged after switching over.
It must be noted that the IP Address Selection Rule is unique for all the possible external
hosts (WebSentinel PC, Genius PC or generic host).