Datalogic Controller SC6000 Installation Manual Page 61

  • Download
  • Add to my manuals
  • Print
  • Page
    / 78
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 60
REDUNDANT SYSTEMS
55
6
6.5.3 Power Supply
Two separate paralleled power supplies are present to supply power both to the controllers
and the scanners. Under normal load conditions, the failure of one of the power supplies is
tolerated by the system. Voltage monitoring is present and used to generate alarms, however
it does not affect the switch over policy.
6.5.4 Dual Ethernet
Each controller (Dual Ethernet models) is able to interface to the host computer through two
different Ethernet networks. The dual Ethernet is intended to allow the physical replication of
the connection to the host computer, however dual Ethernet is not managed by REDS.
6.6 GENIUS CONFIGURATION PARAMETERS
Parameter
Values (default)
Function
Redundancy Parameters
Redundancy Role Parameters
Enable
Enable/Disable
Enables/disables REDS
WebSentinel Operating
Mode
Standard/Redundant
WebSentinel Agent operating mode.
Standard: if the system is
redundant, no diagnostic digital
input information about the Standby
system is reported.
Redundant: diagnostic digital input
information about the Standby
system is reported. The digital input
diagnostic information of the active
controller is replaced with the
diagnostics of both the controllers (4
inputs Active + 4 inputs Standby)
Topology Redundancy Role
Master Alone/Master
Working /Master
Protecting
Topology Role. Explicitly connected
to the Lonworks address of the
controller (0: Working, 63
Protecting). The selection of
Topology Role to
Working/Protecting implies the
default value Active/Standby for the
Redundancy Role (read-only)
IP Address Selection Rule
Redundancy Role (A/S)
/Topology Role (W/P)
Defines the IP address selection
policy for the interface to both
WebSentinel and the Host:
Topology Role: fixed IP address
Redundancy Role: variable IP
depending on the dynamic role
Redundancy Parameters
\Redundancy Switch
Parameters
Active/Standby switch over
configuration parameters
Check Presence Sensor
Failure
Enabled/Disabled
Presence sensor diagnostics affects
the switch over
Presence Sensor Failure
Event Filter
1-10; (5)
Number of times the alarm must be
repeated before the switch over
occurs
Page view 60