4.7 CBX ERROR CODE TABLE
ERROR
CODE
ERROR DESCRIPTION
0x04
FILL TAG FAILED Fill Tag Command Failed
0x05
READ DATA FAILED Read Data Command Failed
0x06
WRITE DATA FAILED Write Data Command Failed
0x07
READ TAG ID FAILED / TAG
SEARCH FAILED
Read Tag ID Command Failed, Tag
Search Command Failed and/or No Tag
Found
0x21
INVALID SYNTAX Command Contained a Syntax Error
0x23
INVALID TAG TYPE Invalid Tag Type Specified
0x30
INTERNAL CONTROLLER
ERROR
Generic Internal Controller Error
0x31
INVALID CONTROLLER TYPE Invalid Controller Type (when Setting
Configuration)
0x34
INVALID VERSION Invalid Software Version Specified (when
Setting Configuration)
0x35
INVALID RESET Invalid Hardware Reset
0x36
WRITE CONFIGURATION
FAILED
Set Configuration Command Failed
0x37
READ CONFIGURATION
FAILED
Get Configuration Command Failed
0x80
UNKNOWN GATEWAY
ERROR
Generic Gateway Error – an
undetermined error occurred.
0x81
COMMAND MALFORMED Generic Command Syntax Error
0x82
COMMAND PROTOCOL
MISMATCH
An invalid protocol value was specified in
the command
0x83
COMMAND INVALID OPCODE An invalid Opcode (Command ID
number) was specified in the command
0x84
COMMAND INVALID
PARAMETER
A parameter specified in the command
was invalid
0x85
COMMAND INVALID
CONTROLLER ID
A Controller ID (Node ID) specified in the
command was invalid, or no controller
detected/present at the specified node
0x86
COMMAND INACTIVE
CONTROLLER ID
A Controller ID (Node ID) specified in the
command is currently inactive.
Page view 40