2.1.3 DIP-Switch Setting
The operating modes are set by configuring one of the eight DIP-switches on the
unit’s main board. To access these DIP-switches, remove the four screws securing
the lid to the base of the enclosure. After removing the lid, locate the DIP-switch
block containing eight small DIP-switches.
The DIP-Switch # 2 selects the Gateway’s Operating Mode, thereby determining
whether the device powers-up in Subnet16 mode or in Mux32 mode.
DIP-Switch 2 ON = Subnet16 (Default Setting)
When this DIP-switch is ON, upon power-up, the Gateway will enter Subnet16
mode, enabling the Subnet16 protocol and expanded feature set.
DIP-Switch 2 OFF = Mux32
When this DIP-switch is OFF, upon power-up, the Gateway will enter Mux32
mode.
The user should NOT modify any other DIP-switch.