Datalogic MAGELLAN 8400 Specifications Page 435

  • Download
  • Add to my manuals
  • Print
  • Page
    / 544
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 434
Standard 2 of 5 (Std 2 of 5) Enable
Product Reference Guide 6-317
Standard 2 of 5 Stitching
Enables/disables stitching for Standard 2 of 5 labels. When parts of a Stan-
dard 2 of 5 bar code are presented to the scanner with this feature enabled,
the bar code parts will be assembled by the scanner’s software, and the data
will be decoded if all bar code proofing requirements are met.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan your selection from the bar codes below. You’ll need to cover
any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
I 2 OF 5 STITCHING = DISABLE
I 2 OF 5 STITCHING = ENABLE
NOTE
Standard 2 of 5 Stitching operates using fixed lengths ONLY. Standard 2 of 5
Length 1 and/or Standard 2 of 5 Length 2 must be properly configured for
stitching to work.