6-204 Magellan
TM
8300/8400
EAN-8 5-Digit Supplemental Label ID
This feature specifies an EAN-8 5-Digit Supplemental label ID to be
added to bar code data.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code,
SET EAN-8 5-DIGIT SUPPLEMENTAL LABEL
ID
below. You’ll need to cover any unused bar codes on this and the
facing page to ensure the scanner reads only the bar code you intend
to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that rep-
resent the desired Label ID characters; entered as two hex pairs. A
table containing the
ASCII Character Set and their corresponding
Hex Values is available in the inside back cover of this manual.
ASCII parameters must be input by scanning a pair of hexadecimal
digits for each character. Thus, to set a two-character value of AB,
bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned.
The selectable range for this option is any hex value from 00 to FF.
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET EAN-8 5-DIGIT SUPPLEMENTAL LABEL ID
NOTE
The programming feature, Label ID Control, designates whether the Label ID
is transmitted as a prefix or suffix or if Label ID is disabled.