Datalogic MAGELLAN 8400 Specifications Page 419

  • Download
  • Add to my manuals
  • Print
  • Page
    / 544
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 418
Interleaved 2 of 5 (I 2 of 5) Enable
Product Reference Guide 6-301
I 2 of 5 Label ID
This feature specifies an I 2 of 5 label ID to be added to bar code data..
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code,
SET I 2 of 5 LABEL ID below. You’ll need to
cover any unused bar codes on this and the facing page to ensure the
scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that rep-
resent the desired Label ID characters; entered as two hex pairs. A
table containing the
ASCII Character Set and their corresponding
Hex Values is available in the inside back cover of this manual.
ASCII parameters must be input by scanning a pair of hexadecimal
digits for each character. Thus, to set a two-character value of AB,
bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned.
The selectable range for this option is any hex value from 00 to FF.
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET I 2 of 5 LABEL ID
NOTE
The programming feature, Label ID Control, designates whether the Label ID
is transmitted as a prefix or suffix or if Label ID is disabled.