Code 93 ENTER/EXIT PROGRAMMING MODE
232
Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Code 93 Set Length 2
This feature specifies one of the barcode lengths for Code 93 Length Control. Length 2 is the
maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length
Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length
does not include start/st
op characters. The length can be set from 1 to 50 characters. A setting of
0 specifies to ignore this length (only one fixed length).
Table 23 provides examples for setting Length 2. See page 303 for detailed instructions on
setting this feature.
Table 23. CODE 93 Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Length)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 93 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Code 93 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the
entry string. You can then start again at the beginning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters