Datalogic GRYPHON Specifications Page 184

  • Download
  • Add to my manuals
  • Print
  • Page
    / 370
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 183
Standard 2 of 5 ENTER/EXIT PROGRAMMING MODE
182
Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Standard 2 of 5 Set Length 2
This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control. Length 2 is
the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed
Length Mode. Length includes the barcode’s check and data characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to i
gnore this length (only
one fixed length).
Table 11 provides examples for setting Length 2. See page 303 for detailed instructions on
setting this feature.
Table 11. Standard 2 of 5 Length 2 Setting Examples
STEP ACTION EXAMPLES
1
Desired Setting (pad with
leading zer
oes)
00 (Ignore This
Length)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT STANDARD 2 OF 5 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Standard 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not
save the en
try string. You can then start again at the begin-
ning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters
Page view 183
1 2 ... 179 180 181 182 183 184 185 186 187 188 189 ... 369 370

Comments to this Manuals

No comments