STS400™ INSTALLATION MANUAL
48
6
SLAVE READERS CONFIGURATION
Same configuration as master except for the following:
READING SYSTEM LAYOUT:
Device Network Setting = Alone o ID-NET
Topology Role = Slave (synchronized)
Slave Address = 1,2,3, …
OPERATING MODES
Acquisition Trigger Delay for SLAVES 1,3, 5,… (odd nodes)
Status = Enabled
Delay Time (x100us) = 20
Acquisition Trigger Delay for SLAVES 2,4,… (even nodes)
Status = Disabled
1D CODES:
Code search priority =
45 Degrees (odd nodes)
Horizontal/Vertical (even nodes)
NOTE
In addition to the above parameters, the master reader may require
changes to the setup parameters that handle the communications between
the STS400™ and the host computer. Refer to the Matrix 410 Reference
Manual and VisiSet™ Help-On-Line for the details.
6.2 BACKUP & RESTORE PROCEDURES
The STS400™ factory default parameter settings are already stored in the External Memory
(BM100 module) inside the CBX500 ATS connection box. After installation, changes to these
parameters must be backed up, overwriting the factory settings.
Additionally, backup files can be created for each specific reader on the STS400™ and
saved to a PC.
6.2.1 Using VisiSet™
The VisiSet™ configuration tool provides the most comprehensive method of calibration and
system configuration is the preferred method for making parameter changes. It also provides
an easy method for performing configuration Backup and Restore.