1
Conveyor Operating Width: This is the effective operative width where the tires can run:
Operating
Width
Maximum Application FOV: This data is the maximum reading width where a barcode can
be found by the STS400™.
Because the barcode is located on or next to the Bead of the tire, the barcode will never be
found at the edges of the Conveyor Operating Width. The Maximum Application FOV
therefore can always be less than the Conveyor Operating Width:
FOV
Operating Width
The figure above shows a sectional view of the tires in order to better understand the
difference between the Maximum Application FOV and the Conveyor Operating Width.
The Maximum Application FOV can be calculated with the following formula:
FOV = Operating Width – 2 * (Minimum Tire HeightBarcode Position Margin)
The Barcode Position Margin takes into account the distance from the Bead where the
barcode could be applied.
Maximum Conveyor Speed: The STS400™ with factory default configuration can support
speeds up to 1 m/s (196.85 fpm, 60 m/min).
NOTE
Higher speeds can be obtained by modifying the configuration, please
contact your local Datalogic representative for feasibility.