Datalogic DS4800 Technical Information Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
DS4800 OM QUICK GUIDE
15
Second Zone Trigger
This parameters defines the number of the input or the phase working as trigger.
Selections:
Phase (available only when working in On Line operating mode)
Input 1
Input 2
Second Zone Trigger Level
This parameter allows setting the active state of the trigger. When the selected state is active, the oscillating
mirror starts working in the second reading zone according to the parameters set:
Selections:
Active Open
Active Closed
Second Zone Oscillating Mode
This parameter defines the oscillating mode of the scanner mirror to be used in the second reading zone:
Selections:
Fixed the oscillating mirror deflects the scan line at a fixed Second Zone Angle
(default 10°).
Continuous the scan line is deflected according to the Second Zone Min-Max Angle and
Second Zone Frequency settings.
Second Zone Angle (degrees)
This parameter is available only when the second reading zone is working in Fixed Second Zone Oscillating
Mode
.
It defines the angle in degrees with respect to the angle perpendicular to the scanner (0°).
The default value is 10°.
Selections:
a value from
-5° to 35°:
Second Zone Min Angle (degrees)
This parameter is available only when the second reading zone is working in Continuous Second Zone
Oscillating Mode
.
It defines the minimum angle for the second zone deflection range with respect to the angle perpendicular to the
scanner (0°).
Selections:
a value from
-5° to 35°:
Second Zone Max Angle (degrees)
This parameter is available only when the second reading zone is working in Continuous Second Zone
Oscillating Mode
.
It defines the maximum angle for the second zone deflection range with respect to the angle perpendicular to the
scanner (0°).
Selections:
a value from
-5° to 35°:
Second Zone Frequency (Hz)
This parameter is available only when working in Continuous Second Zone Oscillating Mode.
It defines the oscillating frequency in Hertz for the second oscillating zone:
Selections:
a value from
0.2 to 20.0 Hertz:
NOTE
The maximum allowable frequency for the given oscillating amplitudes is:
30.5° to 40° 5 Hz
20.5° to 30° 7 Hz
10.5° to 20° 10 Hz
0.5 to 10° 20 Hz
Page view 14