STEP 6 – X-PRESS™ CONFIGURATION
Once Matrix 400™ has calibrated image density, you can configure it for optimal code reading relative to your
application. This configuration can be performed either through the X-PRESS™ Interface or the VisiSet™
configuration program.
LOCATE
1. Enter the Focus function by pressing and holding the X-PRESS™ push
button until the Focus LED is on.
2. Release the button to enter the Focus function. The Blue Diamonds™
turn on.
3. Select a code from your application. Position the code at the center of
the FOV (equidistant from the Blue Diamonds™).
4. Exit the Focus function by pressing the X-PRESS™ push button once.
The Blue Diamonds™ turn off.
READY
green
green
y
ellow
y
ellow
red
SETUP
FOCUS
T
ES
T
LEARN
GOOD
T
RIGGER
COM
STATUS
Figure 12 – X-PRESS™
Interface: Locate Function
SETUP
5. Enter the Setup function by pressing and holding the X-PRESS™ push
button until the Setup LED is on.
6. Release the button to enter the Setup function. The Setup LED will blink
until the procedure is completed.
The Setup procedure ends when the Image Acquisition parameters are
successfully saved in the reader memory, the Setup LED will remain on
continuously and Matrix 400™ emits 3 high pitched beeps.
If the calibration cannot be reached after a timeout of about 5 (five) seconds
Matrix 400™ will exit without saving the parameters to memory, the Setup
LED will not
remain on continuously but it will just stop blinking. In this case
Matrix 400™ emits a long low pitched beep.
7. Exit the Setup function by pressing the X-PRESS™ push button once.
READY
green
green
y
ellow
y
ellow
red
SETUP
FOCUS
T
ES
T
LEARN
GOOD
T
RIGGER
COM
STATUS
Figure 13 – X-PRESS™
Interface: Setup Function
LEARN
8. Enter the Learn function by pressing and holding the X-PRESS™ push
button until the Learn LED is on.
9. Release the button to enter the Learn function. The Learn LED will blink
until the procedure is completed.
The Learn procedure ends when the Image Processing and Decoding
parameters are successfully saved in the reader memory, the Learn LED
will remain on continuously, the Green Spot is activated and Matrix 400™
emits 3 high pitched beeps.
If the calibration cannot be reached after a timeout of about 3 (three)
minutes Matrix 400™ will exit without saving the parameters to memory,
the Learn LED will not
remain on continuously but it will just stop blinking. In
this case Matrix 400™ emits a long low pitched beep.
10. Exit the Setup function by pressing the X-PRESS™ push button once.
READY
green
green
y
ellow
y
ellow
red
SETUP
FOCUS
T
ES
T
LEARN
GOOD
T
RIGGER
COM
STATUS
Figure 14 – X-PRESS™
Interface: Learn Function
If you have used this procedure to configure Matrix 400™ go to step 9.