Global Features
Product Reference Guide 25
Global Maximum Code Length
Global maximum length can be set to qualify data entry. The length is defined
as the actual bar code data length to be sent. bar code labels with lengths
exceeding these limits will be rejected. Ensure that the minimum-length setting
is no greater than the maximum-length setting; otherwise, the labels of the
symbology will not be readable. In particular, you can set the same value for
both minimum and maximum lengths to force decoding of only fixed-length
bar codes. This setting has no effect on certain symbologies of fixed length.
START
MODE BARCODE
Global Maximum length can be set from 0 to 255. To
set this feature, scan the “START” bar code above to
place the unit in Programming Mode, then the “Set
Global Maximum Length,” followed by the digits from
the Alphanumeric table in
Appendix B, Alpha-
Numeric Pad representing your desired maximum
length. Accept your selection by scanning the “SET”
bar code below and finally, exit programming mode by
scanning the “END” barcode below.
DEFAULT SETTING FOR THIS FEATURE: 64
Set Global
Maximum
Length
SET
END