Symbologies
170 QuickScan
TM
QS6500/QS6500BT
Interleaved 2 of 5 — continued
Fixed Length Control
One or two fixed lengths may be configured for Interleaved 2 of 5. Lengths
must be even and must include any check digit that may be in the bar code. If
Length 1 or Length 2 are set to non-zero values, the minimum and maximum
length settings are ignored. To disable fixed lengths, set Length 1 and Length 2
to a value of 00.
To configure this feature:
1. Determine the length settings needed for Fixed Length 1 and Fixed
Length 2, then reference
Appendix A, ASCII Conversion Chart to find the
corresponding hex values for your chosen lengths. Selectable lengths are
from 0x00 to 0x64 (from 0 to 100 decimal).
2. Scan the START bar code below.
3. Scan either the
Set Fixed Length 1 or Set Fixed Length 2 bar code.
4. Turn to
Appendix B, Alpha-Numeric Pad and scan the hex digits represent-
ing the desired length. For example, scan 00 to disable the feature, or 0A
to set the length to 10.
5. Scan the SET bar code to accept the digits scanned.
6. Scan the END bar code to exit Programming Mode.