DEFAULT CONFIGURATION
RS232 Standard DEFAULT SETTINGS
115200 baud, no parity, 8 data bits, 1 stop bit, no handshake, no protocol,
FIFO enabled, intercharacter delay = 0, intercode delay = 0
USB COM Emulation DEFAULT SETTINGS
no handshake, no protocol, FIFO enabled, intercharacter delay = 0, intercode
dela
y
= 0
USB Keyboard Emulation DEFAULT SETTINGS
USA keyboard*, intercharacter delay = 0, intercode delay = 0, FIFO enabled,
keyboard speed = normal
WEDGE Communication DEFAULT SETTINGS
USA keyboard*, CapsLock OFF, CapsLock Auto-Recognition ON, NumLock
OFF, intercharacter delay = 0, intercode delay = 0
DATA FORMAT – Symbology Independent Parameters
custom code identifier disabled, code identifier disabled, code length disabled
Default headers and terminators*:
- RS232: no header, terminator = CR-LF
- USB BULK: no header, terminator = CR-LF
- USB COM: no header, terminator = CR-LF
- USB Generic HID: no header, terminator = CR-LF
- Wedge: no header, terminator = ENTER
- USB Keyboard: no header, terminator = ENTER
DATA FORMAT – Symbology Dependent Parameters
symbology specific format = select all, no headers, no terminators, symbology
character substitution disabled, symbology character deletion disabled
DATA FORMAT – Concatenation
Concatenation disabled, 2 EAN/UPC codes concatenated, Set First
Concatenated Code Length 000 = any length, Set Second Concatenated
Code Length 000 = any length, Set Third Concatenated Code Length 000 =
any length, Set Fourth Concatenated Code Length 000 = any length,
Concatenation with Intercode Delay disabled, Concatenation Timeout 10
seconds, Concatenation Failure Transmission = Tx codes causing failure,
Transmission after Timeout = No code transmission, Concatenation Result
Code ID = No code Identifier
ADVANCED FORMATTING PARAMETERS
format disabled
CAMERA CONTROL
exposure mode = automatic, based on entire image