Datalogic POWERSCAN PD7100 Specifications Page 216

  • Download
  • Add to my manuals
  • Print
  • Page
    / 392
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 215
Symbologies
206 PowerScan
TM
PD7100 Corded
Interleaved 2 of 5 (I 2 of 5) — cont.
2 of 5 Decoding Level
Decoding Levels are used to configure a barcode symbology decoder to be very aggressive
to very conservative depending on a particular customer’s needs.
Choosing Level 1 results in a very conservative decoder at the expense of not being
able to read poorly printed or damaged labels.
Choosing Level 5 results in a very aggressive decoder. This aggressive behavior
allows decoding of poorly printed and damaged labels at the expense of increasing
the likelihood of decoding errors.
Choosing Level 3, which is the default setting, allows the majority of product
labels to be decoded.
There are many factors that determine when to change the decoding level for a particular
symbology. These factors include spots, voids, non-uniform bar/space widths, damaged
labels, etc. that may be experienced in some barcode labels. If there are many hard to read
or damaged labels that cannot be decoded using a conservative setting, increase the de-
coding level to be more aggressive. If the majority of labels are very good quality labels,
or there is a need to decrease the possibility of a decoder error, lower the decoding level
to a more conservative level.
NOTE
This configuration item applies to Interleaved 2 of 5, Datalogic 2 of 5 and
Standard 2 of 5.
Page view 215
1 2 ... 211 212 213 214 215 216 217 218 219 220 221 ... 391 392

Comments to this Manuals

No comments