CBX800 INSTALLATION MANUAL
14
ELECTRICAL CONNECTIONS
POWER SUPPLY
CBX00 can accept power from the connected reading device through the 25-pin connector, or through the
dedicated spring clamp connector (see section Power Source Jumper Settings).
The default jumper setting, requires power to be supplied to the CBX800 through the Vdc and GND pins provided
on the spring clamp terminal connector as shown in Figure 13:
V+
in
Earth
Ground
Power Supply
VGND
Figure 13 - Power Supply Connections
The power must be between 10 and 30 Vdc only.
HOST INTERFACE
CAUTION
Do not connect to the Host Interface spring clamp terminals if using Host Interface Modules
(Fieldbus and non Fieldbus) with the CBX800.
Figure 14 – Host Interface Module
The signals relative to the following Serial interface types are available on the CBX800 spring clamp terminal
blocks.
The Host serial interface type and its parameters (baud rate, data bits, etc.) can be defined by the user via
Genius™ software. The RS485 half duplex is automatically set whenever MUX32 communication protocol
is enabled. For more details refer to the "Communication Settings" section in the Genius™ Help On Line.
Details regarding the connections and use of the interfaces are given in the next paragraphs.