Page view 261
Symbologies
6-174 QuickScan
®
QS6500/QS6500 BT
Code 16K — continued
Code I.D. Selection
The Code I.D. for this symbology consists of one or two user-selectable
ASCII characters. It can be appended previous to or following the trans-
mitted Code 16K bar code data depending on how this feature is
enabled.
Example: Setting the Code 16K Code I.D.
To configure this feature:
1. Determine which character(s) you would like to use to represent
the Code 16K symbology. Reference Appendix A, ASCII Conversion
Chart
to find the corresponding hex values for your chosen charac-
ter(s). In this example we’ll set a Code I.D. of “C” to represent
Code 16K. The value from the table corresponding to ‘’C’ is 43.
This value will be used in a step to follow.
2. Scan the START bar code
3. Scan the SET Code 16K CODE I.D. bar code.
4. Turn to
Appendix B, Alpha-Numeric Pad and scan the bar codes ‘4’
and ‘3’ (the value determined in an earlier step to represent ‘C’).
5. Scan the SET bar code to accept the digits scanned.
6. Turn to the
Data Editing chapter and scan the CODE ID POSI-
TION: BEFORE BAR CODE DATA label.
7. Scan the END bar code to exit Programming Mode.
8. The resulting message string for scanned Code 16K labels would
appear as follows:
Scanned bar code data: 0123456789123
Resulting message string output: C0123456789123
NOTE
Features configured using the
Data Editing chapter are
universal and will affect all symbologies.
Page view 261