Page 1 - Product Reference Guide

PowerScan® 7000BT SRILinear ImagerProduct Reference Guide

Page 2

Getting Started1-2 PowerScan® 7000BT SRIAbout This ManualThis Product Reference Guide (PRG) provides programming instruc-tions for the scanner, plus p

Page 3 - Table of Contents

Data Editing4-18 PowerScan® 7000BT SRINOTES

Page 4 - PowerScan® 7000BT SRI

Product Reference Guide 5-1Chapter 5Bluetooth FeaturesThis section contains features which are specific to radio communica-tions between the scanner a

Page 5 - Product Reference Guide iii

Bluetooth Features5-2 PowerScan® 7000BT SRIAuto Configuration UpdateWhen this feature is enabled, a scanner and its linked Base Station can automatica

Page 6

Auto Flash Memory UpdateProduct Reference Guide 5-3Auto Flash Memory UpdateEnable this feature to allow the Base Station to automatically update a lin

Page 7 - Product Reference Guide v

Bluetooth Features5-4 PowerScan® 7000BT SRINon-Automatic UpdatesUse the following special programming bar code labels to perform a manual, one-time up

Page 8

Battery Charge ModeProduct Reference Guide 5-5Do Not Send Configuration to ScannerIn instances where you do not want the Base Station to automatically

Page 9

Bluetooth Features5-6 PowerScan® 7000BT SRIACK TimeoutACK Timeout configures a duration, selectable in 200-millisecond increments, for the scanner to

Page 10 - About This Manual

Poll Rate TimeoutProduct Reference Guide 5-7Poll Rate TimeoutDuring normal operation, the Base Station regularly signals (polls) for a response from t

Page 11 - Bottom of Base Station

Bluetooth Features5-8 PowerScan® 7000BT SRITransmit HACKThis option allows you to choose when the HACK (Host Acknowledge) should be sent from the Base

Page 12 - Power Connection —

Bluetooth (BT) Beeper FeaturesProduct Reference Guide 5-9Bluetooth (BT) Beeper FeaturesThe settings in this section apply specifically to scanner beep

Page 13 - Link to Base Station

About This ManualProduct Reference Guide 1-3Base Station Connection and Routing — Fully insert the Power Cable and Interface (I/F) Cable connectors i

Page 14 - Paging Feature

Bluetooth Features5-10 PowerScan® 7000BT SRIBT Beep DurationUse this feature to set the duration of configurable BT-specific beeps. Settings are in in

Page 15 - Defaults

Bluetooth (BT) Beeper FeaturesProduct Reference Guide 5-11BT Beep FrequencyThis option selects the frequency (tone or pitch) of the Acknowledge (ACK)

Page 16

Bluetooth Features5-12 PowerScan® 7000BT SRIBT Disconnect BeepWhen enabled, this option allows the scanner to sound (beep) when the scanner disconnect

Page 17 - General Features

Bluetooth (BT) Beeper FeaturesProduct Reference Guide 5-13BT ACK Label BeepThis setting enables or disables the acknowledgement (ACK) beep that indica

Page 18 - 2-2 PowerScan® 7000BT SRI

Bluetooth Features5-14 PowerScan® 7000BT SRIBT Transmission Error BeepEnables or disables the transmission error Beep. This beep indicates a label has

Page 19 - Powerdown Timeout

Bluetooth (BT) Beeper FeaturesProduct Reference Guide 5-15BT In Cradle ChirpThis feature enables or disables a “chirp” sound (a short, high-pitched be

Page 20 - 2-4 PowerScan® 7000BT SRI

Bluetooth Features5-16 PowerScan® 7000BT SRIBT Leash BeepThis feature enables or disables the Leash Beep, which occurs upon dis-connect. When enabled,

Page 21 - LED and Beeper Indicators

Product Reference Guide 6-1Chapter 6SymbologiesThe scanner supports the following symbologies (bar code types). Options for each symbology are include

Page 22 - LED Idle State

Symbologies6-2 PowerScan® 7000BT SRIUPC-AThe following options apply to the UPC-A symbology.Disable/Enable UPC-AWhen disabled, the scanner will not re

Page 23 - Good Read: When to Indicate

UPC-AProduct Reference Guide 6-3UPC-A — continuedSTART/ENDSTATE BAR CODEDisable UPC-AEnable UPC-ADon’t Send Check DigitSendCheck DigitDon’t Expand to

Page 24 - Good Read Beep Control

Getting Started1-4 PowerScan® 7000BT SRIFigure 1-2. Connecting to the HostPower Connection — Plug the AC Adapter in to an approved AC wall socket wit

Page 25 - Good Read Beep Frequency

Symbologies6-4 PowerScan® 7000BT SRIUPC-A — continuedSTART/ENDSTATE BAR CODEDisable Sys-tem Number TransmissionEnable System Number Trans-mission

Page 26 - Good Read Beep Length

UPC-AProduct Reference Guide 6-5UPC-A — continuedUPC-A Minimum ReadsThis feature specifies the minimum number of consecutive times a UPC-A label must

Page 27 - LENGTH BAR CODE

Symbologies6-6 PowerScan® 7000BT SRIUPC-A — continuedIn-store Minimum ReadsThis feature specifies the minimum number of consecutive times an in-store

Page 28 - Good Read Beep Volume

UPC-AProduct Reference Guide 6-7UPC-A — continuedAdd-On TimerThis feature sets the period of time after a UPC-A label is decoded when optional add-on

Page 29 - Scanning Features

Symbologies6-8 PowerScan® 7000BT SRIUPC-EThe following options apply to the UPC-E symbology.Disable/Enable UPC-EWhen disabled, the scanner will not re

Page 30 - Scan Mode — continued

UPC-EProduct Reference Guide 6-9UPC-E — continuedSTART/ENDSTATE BAR CODEDisable UPC-EEnable UPC-EDon’t Send Check DigitSendCheck DigitExclude Sys-tem

Page 31 - Active Scanning Time

Symbologies6-10 PowerScan® 7000BT SRIDon’t Expand UPC-E toUPC-AExpand UPC-E to UPC-ADon’t Expand UPC-E toEAN-13Expand UPC-E to EAN-13UPC-E — continued

Page 32 - Laser Pointer Control

UPC-EProduct Reference Guide 6-11UPC-E — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times a UPC-E label must be de

Page 33 - Product Reference Guide 2-17

Symbologies6-12 PowerScan® 7000BT SRIGTINThe following options apply to the GTIN label data format.Disable/Enable GTINWhen this feature is enabled, th

Page 34 - 2-18 PowerScan® 7000BT SRI

EAN-13Product Reference Guide 6-13EAN-13The following options apply to the EAN-13 symbology.Disable/Enable EAN-13When disabled, the scanner will not r

Page 35 - Features

Linking the Scanner to a Base StationProduct Reference Guide 1-5Linking the Scanner to a Base Station — cont.When the generic Link to Base Station lab

Page 36

Symbologies6-14 PowerScan® 7000BT SRIEAN-13 — continuedSTART/ENDSTATE BAR CODEDisable EAN-13Enable EAN-13Don’t Send Check DigitSendCheck DigitDon’t Tr

Page 37 - Product Reference Guide 3-3

EAN-13Product Reference Guide 6-15TransmitEAN-13 Flag 1 CharDisable ISBNEnable ISBNEAN-13 — continuedSTART/ENDSTATE BAR CODE

Page 38 - Interface Selection

Symbologies6-16 PowerScan® 7000BT SRIEAN-13 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an EAN-13 label mus

Page 39 - Interface Selection — cont

EAN-8Product Reference Guide 6-17EAN-8The following options apply to the EAN-8 symbology.Disable/Enable EAN-8When disabled, the scanner will not read

Page 40

Symbologies6-18 PowerScan® 7000BT SRIEAN-8 — continuedExpand EAN-8 to EAN-13 — Expands EAN-8 data to the EAN-13 data format. Selecting this feature al

Page 41

EAN-8Product Reference Guide 6-19EAN-8 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an EAN-8 label must be d

Page 42

Symbologies6-20 PowerScan® 7000BT SRIAdd-onsAdd-ons (or supplemental characters) are commonly added to the end of UPC/EAN bar codes. The scanner will

Page 43 - Interface Features

Add-onsProduct Reference Guide 6-21Add-ons — continuedSTART/ENDSTATE BAR CODEDisable Optional 2-Digit Add-onsEnable Optional 2-Digit Add-onsDisable Op

Page 44 - RS-232 Interface Features

Symbologies6-22 PowerScan® 7000BT SRIRSS-14The following options apply to the RSS-14 symbology.Disable/Enable RSS-14When this feature is disabled, the

Page 45 - 115200 Baud

RSS-14Product Reference Guide 6-23RSS-14 — continuedSTART/ENDSTATE BAR CODEDisableRSS-14Enable RSS-14DisableUCC/EAN 128 EmulationEnableUCC/EAN 128 Emu

Page 46 - 3-12 PowerScan® 7000BT SRI

Getting Started1-6 PowerScan® 7000BT SRIOptional: Linking the Scanner to a PCA scanner can optionally be linked to a Bluetooth-enabled PC with the ser

Page 47 - Parity = Odd

Symbologies6-24 PowerScan® 7000BT SRIRSS-14 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an RSS-14 label mus

Page 48 - Software Flow Control

RSS-14Product Reference Guide 6-25RSS-14 — continuedRSS-14 2D ComponentThis feature controls the requirement that a 2D label component be decoded when

Page 49 - Product Reference Guide 3-15

Symbologies6-26 PowerScan® 7000BT SRIRSS ExpandedThe following options apply to the RSS Expanded symbology.Disable/Enable RSS ExpandedWhen this featur

Page 50 - 3-16 PowerScan® 7000BT SRI

RSS ExpandedProduct Reference Guide 6-27RSS Expanded — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scann

Page 51 - Product Reference Guide 3-17

Symbologies6-28 PowerScan® 7000BT SRIRSS Expanded — continuedSTART/ENDMODE BAR CODEVariable LengthDecodingFixed Length Decoding

Page 52 - RS-232 Invert

RSS ExpandedProduct Reference Guide 6-29RSS Expanded — continuedRSS Expanded Length 1, Length 2 Pro-gramming Instructions1. Scan the START/END bar cod

Page 53 - Product Reference Guide 3-19

Symbologies6-30 PowerScan® 7000BT SRIRSS Expanded — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an RSS Expand

Page 54 - 3-20 PowerScan® 7000BT SRI

RSS ExpandedProduct Reference Guide 6-31RSS Expanded — continuedRSS Expanded 2D ComponentThis feature controls the requirement that a 2D label compone

Page 55 - Beep on Not on File

Symbologies6-32 PowerScan® 7000BT SRIRSS LimitedThe following options apply to the RSS Limited symbology.Disable/Enable RSS LimitedWhen this feature i

Page 56 - ACK NAK Options

RSS LimitedProduct Reference Guide 6-33RSS Limited — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an RSS Limit

Page 57 - ACK NAK Options — cont

ProgrammingProduct Reference Guide 1-7ProgrammingThis manual contains feature descriptions and bar codes which allow you to reconfigure your scanner.

Page 58 - ACK Character

Symbologies6-34 PowerScan® 7000BT SRIRSS Limited — continuedRSS Limited 2D ComponentThis feature controls the requirement that a 2D label component be

Page 59 - NAK Character

Code 39Product Reference Guide 6-35Code 39The following options apply to the Code 39 symbology.Disable/Enable Code 39When this feature is disabled, th

Page 60 - Retry on ACK NAK Timeout

Symbologies6-36 PowerScan® 7000BT SRICode 39 — continuedSTART/ENDSTATE BAR CODEDisableCode 39EnableCode 39DisableCheck CharCalculationEnableCheck Char

Page 61 - ACK NAK Timeout Value

Code 39Product Reference Guide 6-37Code 39 — continuedSTART/ENDSTATE BAR CODEDon’t TransmitStart/Stop CharactersTransmitStart/Stop CharactersDisableCo

Page 62 - ACK NAK Retry Count

Symbologies6-38 PowerScan® 7000BT SRICode 39 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner will

Page 63 - ACK NAK Error Handling

Code 39Product Reference Guide 6-39Code 39 — continuedSTART/ENDMODE BAR CODEVariable LengthDecodingFixed Length Decoding

Page 64 - 3-30 PowerScan® 7000BT SRI

Symbologies6-40 PowerScan® 7000BT SRICode 39 Length 1, Length 2 Programming Instructions1. Scan the START/END bar code.2. Scan either the Set Length 1

Page 65 - IBM-USB Interface Features

Code 39Product Reference Guide 6-41Code 39 — continuedQuiet ZonesThis feature enables/disables the requirement that quiet zones must be present for Co

Page 66 - 3-32 PowerScan® 7000BT SRI

Symbologies6-42 PowerScan® 7000BT SRICode 39 — continuedCode 39 StitchingEnables/disables stitching for Code 39 labels. When parts of a Code 39 bar co

Page 67

Code 39Product Reference Guide 6-43Code 39 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Code 39 label mus

Page 68 - Wand Emulation — cont

Getting Started1-8 PowerScan® 7000BT SRINOTES

Page 69

Symbologies6-44 PowerScan® 7000BT SRIPharmacode 39The following options apply to the Pharmacode 39 symbology.Disable/Enable Pharmacode 39When this fea

Page 70

Pharmacode 39Product Reference Guide 6-45Pharmacode 39 — continuedStart/Stop CharactersEnables or disables transmission of Pharmacode 39 start/stop ch

Page 71

Symbologies6-46 PowerScan® 7000BT SRICode 128 and EAN 128Enable/Disable Code 128 — When this feature is disabled, the scan-ner will not read Cod 128 b

Page 72

Code 128 and EAN 128Product Reference Guide 6-47Code 128 and EAN 128 — continuedTransmit Function CharactersEnables/disables transmission of Code128 f

Page 73 - Symbology Conversion

Symbologies6-48 PowerScan® 7000BT SRICode 128 and EAN 128 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the

Page 74 - Keyboard Wedge/USB Keyboard

Code 128 and EAN 128Product Reference Guide 6-49Code 128 and EAN 128 — continuedSTART/ENDMODE BAR CODEVariable LengthDecodingFixed Length Decoding

Page 75 - Product Reference Guide 3-41

Symbologies6-50 PowerScan® 7000BT SRICode 128 and EAN 128 — continuedCode 128 Length 1, Length 2 Programming Instructions1. Scan the START/END bar cod

Page 76 - 3-42 PowerScan® 7000BT SRI

Code 128 and EAN 128Product Reference Guide 6-51Code 128 and EAN 128 — continuedCode 128 StitchingEnables/disables stitching for Code 128 labels. When

Page 77

Symbologies6-52 PowerScan® 7000BT SRICode 128 and EAN 128 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Co

Page 78 - 3-44 PowerScan® 7000BT SRI

Interleaved 2 of 5Product Reference Guide 6-53Interleaved 2 of 5The following options apply to the Interleaved 2 of 5 (I 2 of 5) symbol-ogy.Disable/En

Page 79 - Product Reference Guide 3-45

Product Reference Guide 2-1Chapter 2General FeaturesDouble Read TimeoutThe Double Read Timeout feature sets a time limit that determines how much time

Page 80 - 3-46 PowerScan® 7000BT SRI

Symbologies6-54 PowerScan® 7000BT SRIInterleaved 2 of 5 — continuedSTART/ENDSTATE BAR CODEDisableInterleaved2 of 5EnableInterleaved2 of 5DisableCheck

Page 81 - Quiet Interval

Interleaved 2 of 5Product Reference Guide 6-55Interleaved 2 of 5 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enable

Page 82 - 3-48 PowerScan® 7000BT SRI

Symbologies6-56 PowerScan® 7000BT SRIInterleaved 2 of 5 — continuedSTART/ENDMODE BAR CODEVariable LengthDecodingFixed Length Decoding

Page 83

Interleaved 2 of 5Product Reference Guide 6-57Interleaved 2 of 5 — continuedInterleaved 2 of 5 Length 1, Length 2 Pro-gramming Instructions1. Scan the

Page 84 - 00 - 20 Characters (ASCII)

Symbologies6-58 PowerScan® 7000BT SRIInterleaved 2 of 5 — continuedInterleaved 2 of 5 StitchingEnables/disables stitching for Interleaved 2 of 5 label

Page 85 - Appendix C

Interleaved 2 of 5Product Reference Guide 6-59Interleaved 2 of 5 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive time

Page 86 - 4-4 PowerScan® 7000BT SRI

Symbologies6-60 PowerScan® 7000BT SRICodabarThe following options apply to the Codabar symbology.Disable/Enable CodabarWhen this feature is disabled,

Page 87 - Product Reference Guide 4-5

CodabarProduct Reference Guide 6-61Codabar — continuedSTART/ENDSTATE BAR CODEDisableCodabarEnableCodabarDisableCheck CharVerificationEnableCheck CharV

Page 88 - AIM ID — continued

Symbologies6-62 PowerScan® 7000BT SRICodabar — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner will

Page 89 - Label ID

CodabarProduct Reference Guide 6-63Codabar — continuedSTART/ENDMODE BAR CODEVariable LengthDecodingFixed Length Decoding

Page 90 - Label ID — continued

General Features2-2 PowerScan® 7000BT SRIDouble Read Timeout — continuedSTART/ENDDURATION BAR CODE0.5 Second0.6 Second0.7 Second0.8 Second0.9 Second1

Page 91

Symbologies6-64 PowerScan® 7000BT SRICodabar — continuedCodabar Length 1, Length 2 Programming Instructions1. Scan the START/END bar code.2. Scan eith

Page 92

CodabarProduct Reference Guide 6-65Codabar — continuedQuiet ZonesThis feature enable/disables the requirement that quiet zones must be present for Cod

Page 93

Symbologies6-66 PowerScan® 7000BT SRICodabar — continuedStart/Stop Character TypeCodabar has four pairs of Start/Stop patterns. Select one pair to mat

Page 94

CodabarProduct Reference Guide 6-67Codabar — continuedSTART/ENDSTATE BAR CODEStart/Stop Type: ABCD/TN*EStart/Stop Type: ABCD/ABCDStart/Stop Type: abcd

Page 95

Symbologies6-68 PowerScan® 7000BT SRICodabar — continuedSTART/ENDSTATE BAR CODEDisable Start/Stop Char MatchEnable Start/Stop Char Match

Page 96

CodabarProduct Reference Guide 6-69Codabar — continuedCodabar StitchingEnables/disables stitching for Codabar labels. When parts of a Codabar label ar

Page 97 - Case Conversion

Symbologies6-70 PowerScan® 7000BT SRICodabar — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Codabar label m

Page 98 - Character Conversion

Code 93Product Reference Guide 6-71Code 93The following options apply to the Code 93 symbology.Disable/Enable Code 93When this feature is disabled, th

Page 99 - Product Reference Guide 4-17

Symbologies6-72 PowerScan® 7000BT SRICode 93 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner will

Page 100 - Data Editing

Code 93Product Reference Guide 6-73Code 93 — continuedSTART/ENDMODE BAR CODEVariable LengthDecodingFixed Length Decoding

Page 101 - Bluetooth Features

Powerdown TimeoutProduct Reference Guide 2-3Powerdown TimeoutThe Powerdown Timeout feature sets the time for automatically switching the scanner off w

Page 102 - Auto Configuration Update

Symbologies6-74 PowerScan® 7000BT SRICode 93 — continuedCode 93 Length 1, Length 2 Programming Instructions1. Scan the START/END bar code.2. Scan eith

Page 103 - Auto Flash Memory Update

Code 93Product Reference Guide 6-75Code 93 — continuedCode 93 StitchingEnables/disables stitching for Code 93 bar codes. When parts of a Code 93 label

Page 104 - Non-Automatic Updates

Symbologies6-76 PowerScan® 7000BT SRICode 93 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Code 93 label m

Page 105 - Battery Charge Mode

Code 11Product Reference Guide 6-77Code 11The following options apply to the Code 11 symbology.Disable/Enable Code 11When this feature is disabled, th

Page 106 - ACK Timeout

Symbologies6-78 PowerScan® 7000BT SRICode 11 — continuedNumber of Check CharactersSpecifies the number of Code 11 check characters (one or two) to be

Page 107 - Poll Rate Timeout

Code 11Product Reference Guide 6-79Code 11 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner will de

Page 108 - Transmit HACK

Symbologies6-80 PowerScan® 7000BT SRICode 11 — continuedSTART/ENDMODE BAR CODEVariable LengthDecodingFixed Length Decoding

Page 109 - BT Beep Volume

Code 11Product Reference Guide 6-81Code 11 — continuedCode 11 Length 1, Length 2 Programming Instructions1. Scan the START/END bar code.2. Scan either

Page 110 - BT Beep Duration

Symbologies6-82 PowerScan® 7000BT SRICode 11 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Code 11 label m

Page 111 - BT Beep Frequency

MSI/PlesseyProduct Reference Guide 6-83MSI/PlesseyThe following options apply to the MSI/Plessey symbology.Disable/Enable MSI/PlesseyWhen this feature

Page 112 - BT Disconnect Beep

Datalogic Scanning, Inc.959 Terry StreetEugene, Oregon 97402Telephone: (541) 683-5700Fax: (541) 345-7140An Unpublished Work - All rights reserved. No

Page 113 - BT ACK Label Beep

General Features2-4 PowerScan® 7000BT SRI15 Minutes30 Minutes1 HourSTART/ENDDURATION BAR CODE

Page 114 - BT Transmission Error Beep

Symbologies6-84 PowerScan® 7000BT SRIMSI/Plessey — continuedSTART/ENDSTATE BAR CODEDisableMSI/PlesseyEnableMSI/PlesseyDisableCheck DigitVerificationEn

Page 115 - BT In Cradle Chirp

MSI/PlesseyProduct Reference Guide 6-852-DigitCheck DigitVerificationDisableCheck DigitTransmissionEnableCheck DigitTransmissionMSI/Plessey — continue

Page 116 - BT Leash Beep

Symbologies6-86 PowerScan® 7000BT SRIMSI/Plessey — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner w

Page 117 - Symbologies

MSI/PlesseyProduct Reference Guide 6-87MSI/Plessey — continuedSTART/ENDMODE BAR CODEVariable LengthDecodingFixed Length Decoding

Page 118 - System Number Transmission

Symbologies6-88 PowerScan® 7000BT SRIMSI/Plessey — continuedMSI/Plessey Length 1, Length 2 Program-ming Instructions1. Scan the START/END bar code.2.

Page 119 - UPC-A — continued

MSI/PlesseyProduct Reference Guide 6-89MSI/Plessey — continuedMSI/Plessey StitchingEnables/disables stitching for MSI/Plessey bar codes. When parts of

Page 120

Symbologies6-90 PowerScan® 7000BT SRIMSI/Plessey — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an MSI/Plessey

Page 121

Standard 2 of 5Product Reference Guide 6-91Standard 2 of 5The following options apply to the Standard 2 of 5 symbology.Disable/Enable Standard 2 of 5W

Page 122

Symbologies6-92 PowerScan® 7000BT SRIStandard 2 of 5 — continuedSTART/ENDSTATE BAR CODEDisableStd 2 of 5EnableStd 2 of 5DisableCheck DigitVerification

Page 123

Standard 2 of 5Product Reference Guide 6-93Standard 2 of 5 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the

Page 124 - Expand UPC-E to EAN13

LED and Beeper IndicatorsProduct Reference Guide 2-5LED and Beeper IndicatorsThe features provided in this section concern general system LED and Beep

Page 125 - UPC-E — continued

Symbologies6-94 PowerScan® 7000BT SRIStandard 2 of 5 — continuedSTART/ENDMODE BAR CODEVariable LengthDecodingFixed Length Decoding

Page 126

Standard 2 of 5Product Reference Guide 6-95Standard 2 of 5 — continuedStandard 2 of 5 Length 1, Length 2 Pro-gramming Instructions1. Scan the START/EN

Page 127

Symbologies6-96 PowerScan® 7000BT SRIStandard 2 of 5 — continuedStandard 2 of 5 StitchingEnables/disables stitching for Standard 2 of 5 bar codes. Whe

Page 128 - Disable/Enable GTIN

Standard 2 of 5Product Reference Guide 6-97Standard 2 of 5 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times a St

Page 129 - EAN-13 Flag 1 Character

Symbologies6-98 PowerScan® 7000BT SRIPDF 417The following options apply to the PDF 417 symbology.Disable/Enable PDF 417When this feature is disabled,

Page 130 - EAN-13 — continued

PDF 417Product Reference Guide 6-99PDF 417 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the scanner will de

Page 131

Symbologies6-100 PowerScan® 7000BT SRIPDF 417 — continuedSTART/ENDMODE BAR CODEVariable LengthDecodingFixed Length Decoding

Page 132

PDF 417Product Reference Guide 6-101PDF 417 — continuedPDF 417 Length 1, Length 2 Programming Instructions1. Scan the START/END bar code.2. Scan eithe

Page 133 - Disable/Enable EAN-8

Symbologies6-102 PowerScan® 7000BT SRIPDF 417 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times a PDF 417 label m

Page 134 - EAN-8 — continued

Micro PDF 417Product Reference Guide 6-103Micro PDF 417The following options apply to the Micro PDF 417 symbology.Disable/Enable Micro PDF 417When thi

Page 135

General Features2-6 PowerScan® 7000BT SRILED Idle StateSpecifies state of scanner’s LED when the scanner is ready to read a bar code.STARTSTATE BAR CO

Page 136 - 6-20 PowerScan® 7000BT SRI

Symbologies6-104 PowerScan® 7000BT SRIMicro PDF 417 — continuedPDF 128 EmulationDepending upon the other configuration features listed below, this fea

Page 137 - Add-ons — continued

Micro PDF 417Product Reference Guide 6-105Micro PDF 417 — continuedLength ControlFixed Length Decoding — When fixed length decoding is enabled, the sc

Page 138 - UCC/EAN 128 Emulation

Symbologies6-106 PowerScan® 7000BT SRIMicro PDF 417 — continuedSTART/ENDMODE BAR CODEVariable LengthDecodingFixed Length Decoding

Page 139 - RSS-14 — continued

Micro PDF 417Product Reference Guide 6-107Micro PDF 417 — continuedMicro PDF 417 Length 1, Length 2 Pro-gramming Instructions1. Scan the START/END bar

Page 140

Symbologies6-108 PowerScan® 7000BT SRIMicro PDF 417 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times a Micro PDF

Page 141

Product Reference Guide A-1Appendix AProduct SpecificationsOptical and Read Performance ParametersParameter SpecificationScanning Width2” wide at 1”

Page 142 - RSS Expanded

A-2 PowerScan® 7000BT SRIPhysical Properties: ScannerPhysical Properties: Base StationElectrical Parameters: Base StationParameter SpecificationDimens

Page 143 - RSS Expanded — continued

Environmental Parameters: ScannerProduct Reference Guide A-3Environmental Parameters: ScannerParameter SpecificationMechanical Shock50 drops from 6.5

Page 144

A-4 PowerScan® 7000BT SRINOTES

Page 145

Product Reference Guide B-1Appendix BCable PinoutsStandard Cable Pinouts (Primary Interface Cables)RS-232IBM Port 5B/9B/1712CTS34RTS5 RXD6TXD78VCC IN

Page 146

LED and Beeper IndicatorsProduct Reference Guide 2-7Good Read: When to IndicateThis feature specifies when the scanner will provide indication (beep a

Page 147

Cable PinoutsB-2 PowerScan® 7000BT SRIIBM USBUSB & USB KeyboardWand Emulation1234D -56D +78VIN9GND101234D -56D +78 VBUS_VIN9GND10123 WAND~45678 VC

Page 148 - RSS Limited

Standard Cable Pinouts (Primary Interface Cables)Product Reference Guide B-3Keyboard Wedge12 KB_DATA3 AT_CLK4 KB_CLK56 AT_DATA78VCC_IN9GND10Pin 110 Po

Page 149 - RSS Limited — continued

Cable PinoutsB-4 PowerScan® 7000BT SRINOTES

Page 150

Product Reference Guide C-1Appendix CAlpha-Numeric PadABCDEF

Page 151 - Code 39 Full ASCII

C-2 PowerScan® 7000BT SRIAlpha-Numeric Pad1230987654

Page 152 - Code 39 — continued

Product Reference Guide D-1Appendix DDefault SettingsStandard Feature DefaultsThe table immediately below lists the default settings for the standard

Page 153

D-2 PowerScan® 7000BT SRIInterface Selection RS-232 Std.Interface as requiredIBM Default:IBM Port 9BWincor/Nixdorf Default: RS-232-WNKeyboard Wedge De

Page 154

Standard Feature DefaultsProduct Reference Guide D-3RS-232 Invert Disable 3-18Beep on ASCII BEL Enable 3-21Beep on Not on File Enable 3-21ACK NAK Opti

Page 155

D-4 PowerScan® 7000BT SRIWand Emulation:Transmit Trailing Noise—Wand Emulation:Enable3-37Wand Emulation:Symbology Conver-sion—Wand Emulation:No Conver

Page 156 - Instructions

Standard Feature DefaultsProduct Reference Guide D-5UPC-A w/P2 Addon Label IDA 4-8UPC-A w/P5 Addon Label IDA 4-8UPC-A w/C128 Addon Label IDA 4-9UPC-E

Page 157

General Features2-8 PowerScan® 7000BT SRIGood Read Beep ControlThis feature enables/disables the scanner’s ability to beep upon a success-ful decode o

Page 158

D-6 PowerScan® 7000BT SRIISBN Label ID IWincor/Nixdorf:‘A’4-10GTIN Label ID G 4-11GTIN w/P2 addon Label IDG2 4-11GTIN w/P5 addon Label IDG5 4-11GTIN w

Page 159

Standard Feature DefaultsProduct Reference Guide D-7Code 93 Label ID &Wincor/Nixdorf:“L’4-13Code 11 Label ID CE 4-13MSI/Plessey Label ID @Wincor/N

Page 160 - Pharmacode 39

D-8 PowerScan® 7000BT SRIBT Disconnect Beep Enable 5-12BT ACK Label Beep Enable 5-13BT Transmission Error BeepEnable 5-14BT In Cradle Chirp Enable 5-1

Page 161 - Pharmacode 39 — continued

Standard Feature DefaultsProduct Reference Guide D-9UPC-E Minimum Reads2 6-11Disable/Enable GTIN Disable 6-12Disable/EnableEAN-13Enable 6-13EAN-13 Che

Page 162 - Code 128 and EAN 128

D-10 PowerScan® 7000BT SRIRSS-14 2DComponentDisable 6-25Disable/Enable RSS ExpandedDisable 6-26UCC/EAN 128EmulationDisable 6-26RSS Expanded Length Con

Page 163 - Transmit Function Characters

Standard Feature DefaultsProduct Reference Guide D-11Code 39 Start/Stop CharactersDon’tTransmit6-35Code 39 Full ASCII Disable 6-35Code 39Length Contro

Page 164 - Length Control

D-12 PowerScan® 7000BT SRICode 128Minimum Reads1 6-52Disable/Enable Inter-leaved 2 of 5Disable 6-53I 2 of 5 Check Digit CalculationDisable 6-53I 2 of

Page 165 - Product Reference Guide 6-49

Standard Feature DefaultsProduct Reference Guide D-13Codabar Start/Stop Char. TransmissionEnable 6-66Codabar Start/Stop Character MatchDisable 6-66Cod

Page 166

D-14 PowerScan® 7000BT SRIDisable/EnableMSI/PlesseyDisable 6-83MSI/Plessey Check Digit VerificationDisable 6-83MSI/Plessey Check Digit Transmit1-Digit

Page 167 - Code 128 Stitching

Standard Feature DefaultsProduct Reference Guide D-15PDF 417Length ControlVariable Length6-99PDF 417 Length 1 1 6-101PDF 417 Length 2 600 6-101PDF 417

Page 168 - Minimum Reads

LED and Beeper IndicatorsProduct Reference Guide 2-9Good Read Beep FrequencyAdjusts the good read beep to sound at a selectable low, medium or high fr

Page 169 - Interleaved 2 of 5

D-16 PowerScan® 7000BT SRINOTES

Page 170 - 6-54 PowerScan® 7000BT SRI

Product Reference Guide E-1Appendix EKeyboard FunctionKey MappingsKeyboard Model Cross ReferenceTa bl e E- 2 summarizes the keyboard models, their de

Page 171

E-2 PowerScan® 7000BT SRITable E-1. Keyboard Model Cross ReferenceModel Type I/F IDTrans-mission ProtocolScancodeSetFunc.KeyMap SupportUseCountryModeP

Page 172 - 6-56 PowerScan® 7000BT SRI

Keyboard Model Cross ReferenceProduct Reference Guide E-3Table E-2. Scanset 1 Function Key MapASCII (hex)ASCII code Key Scancode00 NUL ALT right Mak

Page 173 - Product Reference Guide 6-57

E-4 PowerScan® 7000BT SRITable E-3. Scanset 2 Function Key MapASCII (hex)ASCII code Key Scancode00 NUL ALT right Make E0h 11h01 SOH ALT right Break

Page 174 - Interleaved 2 of 5 Stitching

Keyboard Model Cross ReferenceProduct Reference Guide E-5Table E-4. Scanset 3, 102-Key Function Key MapASCII (hex) ASCII code Key Scancode00 NUL ALT r

Page 175

E-6 PowerScan® 7000BT SRITable E-5. Scanset 3 122-Key Function Key MapASCII (hex) ASCII code Key Scancode00 NUL ALT Right Make 39h01 SOH ALT Right Br

Page 176 - Check Character Verification

Keyboard Model Cross ReferenceProduct Reference Guide E-7Table E-6. Japanese DOS Function Key MapASCII value ASCII code Key Scancode00h NUL ALT right

Page 177 - Codabar — continued

E-8 PowerScan® 7000BT SRITable E-7. NEC 9801-Key Function Key MapASCII value ASCII code Key Scancode00h NUL unused n/a01h SOH CR 1Ch02h STX CAPS LOCK

Page 178

Keyboard Model Cross ReferenceProduct Reference Guide E-9Table E-8. USB Keyboard Function Key Usage MapASCII Key Value Usage Name00 NUL ALT right Make

Page 179

General Features2-10 PowerScan® 7000BT SRIGood Read Beep LengthSpecifies the duration of a good read beep.START/ENDLENGTH BAR CODE60msec80msec100msec1

Page 180

E-10 PowerScan® 7000BT SRINOTES

Page 181

Product Reference Guide F-1Appendix FHost CommandsAccepting RS-232 CommandsThe scanner responds to the following RS-232 commands:If one of the above

Page 182

F-2 PowerScan® 7000BT SRINOTES

Page 183

Product Reference Guide G-1Appendix GSample Symbols0 123456 78901234567890Code 1289 780330 290951BC321123456-9$123456UPC-ACode 128Code 39Code 93I

Page 184

G-2 PowerScan® 7000BT SRISample Symbols(01)00123456789012Car RegistrationPDF417RSS-140100123456789050RSS Expanded

Page 185

Product Reference Guide H-1Appendix HBeeper/LEDIndicationsBeep IndicationsBeep Type Description BehaviorAcknowledge (ACK)LabelA label has been sent to

Page 186

H-2 PowerScan® 7000BT SRIUnlinkThe scanner has unlinked from the Base Station.Beep will soundHigh-medium-low.PagingBase Station is paging the scanner.

Page 187 - Disable/Enable Code 93

LED IndicationsProduct Reference Guide H-3LED IndicationsLED Indication BehaviorApplies to:Base StationScannerLinking in progress Yellow LED blinks at

Page 188 - Code 93 — continued

H-4 PowerScan® 7000BT SRIError CodesUpon startup, if the scanner sounds a long tone, this means the scanner has not passed its automatic Selftest and

Page 189

Error CodesProduct Reference Guide H-5NOTES

Page 190

LED and Beeper IndicatorsProduct Reference Guide 2-11Good Read Beep Length — continuedSTART/ENDLENGTH BAR CODE180msec200msec

Page 191

H-6 PowerScan® 7000BT SRINOTES

Page 192

ASCII ChartASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.HexNo.NULSOHSTXETXEOTENQACKBELBSHTLFVTFFCRSOSIDLEDC1DC2DC3DC4NAKSYNETBCANE

Page 193 - Disable/Enable Code 11

©2006-2007 Datalogic Scanning, Inc. R44-2710 (Rev. A) 4/07AustraliaDatalogic Scanning Pty LtdNorth Ryde, AustraliaTelephone: [61] (2) 9870 3200Fax: [

Page 194 - Code 11 — continued

General Features2-12 PowerScan® 7000BT SRIGood Read Beep VolumeSelects the beeper volume (loudness) upon a good read beep. There are three selectable

Page 195

Scanning FeaturesProduct Reference Guide 2-13Scanning FeaturesScan ModeSelects the scan operating mode for the scanner. Selections are:• Single — When

Page 196

Product Reference Guide iTable of ContentsAbout This Manual ... 1-2Manual Co

Page 197

General Features2-14 PowerScan® 7000BT SRIScan Mode — continuedSTART/ENDMODE BAR CODESingleTriggerlessStandStand w/Illum

Page 198

Scanning FeaturesProduct Reference Guide 2-15Active Scanning TimeThis setting determines the amount of time the scanner continues to scan in triggerle

Page 199 - MSI/Plessey

General Features2-16 PowerScan® 7000BT SRIActive Scanning Time — continuedLaser Pointer ControlWhen the trigger is pressed and Scan Mode is set to Sin

Page 200 - MSI/Plessey — continued

Scanning FeaturesProduct Reference Guide 2-17Laser Pointer Control — continuedSTART/ENDDURATION BAR CODEDisable0.1 Seconds0.2 Seconds0.3 Seconds0.4 Se

Page 201

General Features2-18 PowerScan® 7000BT SRILaser Pointer Control — continuedSTART/ENDDURATION BAR CODE0.6 Seconds0.8 Seconds1 Second1.2 Seconds1.5 Seco

Page 202

Product Reference Guide 3-1Chapter 3Interface RelatedFeaturesAt the time of this writing, the Scanner supports the interfaces listed in Tab le 3 - 1.

Page 203

Interface Related Features3-2 PowerScan® 7000BT SRITable 3-1. Interfaces SupportedRS-232 Page Keyboard Wedge PageRS-232 Standard3-10Keyboard Wedge HaR

Page 204

Product Reference Guide 3-3Table 3-2. Keyboard Wedge Interface ReferenceI/F Type PCs SupportedA PC/XT w/Alternate Key EncodingBAT, PS/2 25-286, 30-286

Page 205

Interface Related Features3-4 PowerScan® 7000BT SRIInterface SelectionSTART/ENDINTERFACE BAR CODERS-232StandardRS-232Wincor-NixdorfIBM 4683Port 5BIBM

Page 206

Interface SelectionProduct Reference Guide 3-5Interface Selection — cont.START/ENDINTERFACE BAR CODEKeyboardWedge AKeyboardWedge BKeyboardWedge CKeybo

Page 207 - Standard 2 of 5

ii PowerScan® 7000BT SRIIBM Transmit Labels in Code 39 Format ... 3-32Wand Emulation ...

Page 208 - Standard 2 of 5 — continued

Interface Related Features3-6 PowerScan® 7000BT SRIInterface Selection — cont.START/ENDINTERFACE BAR CODEKeyboardWedge HKeyboardWedge IKeyboardWedge J

Page 209

Interface SelectionProduct Reference Guide 3-7Interface Selection — cont.START/ENDINTERFACE BAR CODEKeyboardWedge OKeyboardWedge PKeyboardWedge QKeybo

Page 210

Interface Related Features3-8 PowerScan® 7000BT SRIInterface Selection — cont.START/ENDINTERFACE BAR CODEKeyboardWedge UKeyboardWedge VKeyboardWedge W

Page 211

Interface FeaturesProduct Reference Guide 3-9Interface FeaturesGlobal Interface FeaturesSTART/ENDSTATE BAR CODEObey HostCommandsIgnore HostCommandsHos

Page 212

Interface Related Features3-10 PowerScan® 7000BT SRIRS-232 Interface FeaturesSTART/ENDBAUD RATE BAR CODE1200 Baud2400 Baud4800 Baud9600 Baud19200 Baud

Page 213

Interface FeaturesProduct Reference Guide 3-11RS-232 Interface Features — cont.START/ENDBAUD RATE BAR CODE57600 Baud115200 Baud

Page 214 - Disable/Enable PDF 417

Interface Related Features3-12 PowerScan® 7000BT SRIRS-232 Interface Features — cont.START/ENDSTATE BAR CODE7 Data Bits8 Data Bits1 Stop Bit2 Stop Bit

Page 215 - PDF 417 — continued

Interface FeaturesProduct Reference Guide 3-13RS-232 Interface Features — cont.START/ENDSTATE BAR CODEParity = EvenParity = Odd

Page 216

Interface Related Features3-14 PowerScan® 7000BT SRIRS-232 Interface Features — cont.Hardware Flow ControlDisable Hardware Control — The scanner trans

Page 217

Interface FeaturesProduct Reference Guide 3-15RS-232 Interface Features — cont.START/ENDSTATE BAR CODEDisableHardwareControlEnable CTS Flow ControlEna

Page 218

Product Reference Guide iiiMinimum Reads ... 6-11GTIN ...

Page 219 - Micro PDF 417

Interface Related Features3-16 PowerScan® 7000BT SRIInterchar Delay = 30 msecInterchar Delay = 40 msecInterchar Delay = 50 msecInterchar Delay = 60 ms

Page 220 - Micro PDF 417 — continued

Interface FeaturesProduct Reference Guide 3-17Interchar Delay = 90 msecDisableSoftware Flow ControlEnableSoftware Flow ControlRS-232 Interface Feature

Page 221

Interface Related Features3-18 PowerScan® 7000BT SRIRS-232 Interface Features — cont.Host EchoWhen enabled, this feature passes all data through the s

Page 222

Interface FeaturesProduct Reference Guide 3-19RS-232 Interface Features — cont.START/ENDSTATE BAR CODEDisable Host EchoEnable Host EchoHost Echo Quiet

Page 223

Interface Related Features3-20 PowerScan® 7000BT SRIHost Echo Quiet Interval= 40msecHost Echo Quiet Interval= 50msecHost Echo Quiet Interval= 60msecHo

Page 224

Interface FeaturesProduct Reference Guide 3-21Beep on ASCII BELEnables/disables ability of scanner to beep (sound a good read tone) on receiving an AS

Page 225 - Product Specifications

Interface Related Features3-22 PowerScan® 7000BT SRIACK NAK OptionsThis enables/disables the ability of the scanner to support the RS-232 ACK/NAK prot

Page 226 - Physical Properties: Scanner

Interface FeaturesProduct Reference Guide 3-23ACK NAK Options — cont.START/ENDSTATE BAR CODEDisable ACK NAKEnable ACK NAK forTransmissionEnable ACK NA

Page 227 - Product Reference Guide A-3

Interface Related Features3-24 PowerScan® 7000BT SRIRS-232 Interface Features — cont.ACK CharacterSTART/ENDMODE BAR CODESets the ACK character from th

Page 228 - A-4 PowerScan® 7000BT SRI

Interface FeaturesProduct Reference Guide 3-25RS-232 Interface Features — cont.NAK CharacterSTART/ENDMODE BAR CODESets the NAK character from the set

Page 229 - Cable Pinouts

iv PowerScan® 7000BT SRIInterleaved 2 of 5 ...6-53Disable/Enable Interleaved

Page 230 - Wand Emulation

Interface Related Features3-26 PowerScan® 7000BT SRIRS-232 Interface Features — cont.Retry on ACK NAK TimeoutEnables/disables retry after the configur

Page 231 - 10 Position RJ

Interface FeaturesProduct Reference Guide 3-27RS-232 Interface Features — cont.ACK NAK Timeout ValueSTART/ENDMODE BAR CODEThis item specifies the time

Page 232

Interface Related Features3-28 PowerScan® 7000BT SRIRS-232 Interface Features — cont.ACK NAK Retry CountSTART/ENDMODE BAR CODEThis feature sets the nu

Page 233 - Alpha-Numeric Pad

Interface FeaturesProduct Reference Guide 3-29RS-232 Interface Features — cont.ACK NAK Error HandlingThis item specifies the method the scanner will u

Page 234

Interface Related Features3-30 PowerScan® 7000BT SRIRS-232 Interface Features — cont.Transmission Failure IndicationEnables/disables bad-label indicat

Page 235 - Default Settings

Interface FeaturesProduct Reference Guide 3-31IBM-USB Interface FeaturesIBM-USB Device usageThe IBM-USB protocol allows for the scanner to be identifi

Page 236 - D-2 PowerScan® 7000BT SRI

Interface Related Features3-32 PowerScan® 7000BT SRIIBMIBM Transmit Labels in Code 39 FormatThis feature enables/disables scanner's ability to se

Page 237 - Product Reference Guide D-3

Interface FeaturesProduct Reference Guide 3-33Wand EmulationSupported SymbologiesThe Wand Emulation interface will transmit bar code data as a wand de

Page 238 - D-4 PowerScan® 7000BT SRI

Interface Related Features3-34 PowerScan® 7000BT SRIWand Emulation — cont.Bar/Space Polarity Low/High — Black will be transmitted as a low voltage lev

Page 239 - Product Reference Guide D-5

Interface FeaturesProduct Reference Guide 3-35Wand Emulation — cont.START/ENDSTATE BAR CODEWand Idle State = LowWand Idle State = High

Page 240 - D-6 PowerScan® 7000BT SRI

Product Reference Guide vPDF 417 Length 1, Length 2 Programming Instructions ...6-101Minimum Reads ...

Page 241 - Product Reference Guide D-7

Interface Related Features3-36 PowerScan® 7000BT SRIWand Emulation — cont.Signal SpeedThe speed of the transmission can be set. This selects the widt

Page 242 - D-8 PowerScan® 7000BT SRI

Interface FeaturesProduct Reference Guide 3-37Wand Emulation — cont.Transmit Trailing NoiseEnables/disables the ability of the scanner to generate noi

Page 243 - Product Reference Guide D-9

Interface Related Features3-38 PowerScan® 7000BT SRIWand Emulation — cont.Transmit Leading NoiseEnables/disables ability of scanner to generate noise

Page 244 - D-10 PowerScan® 7000BT SRI

Interface FeaturesProduct Reference Guide 3-39Symbology ConversionWand Emulation can convert all bar codes to a single symbology. Choices are:• No Con

Page 245 - Product Reference Guide D-11

Interface Related Features3-40 PowerScan® 7000BT SRIKeyboard Wedge/USB KeyboardAs a keyboard interface, the scanner supports most popular PCs and IBM

Page 246 - D-12 PowerScan® 7000BT SRI

Interface FeaturesProduct Reference Guide 3-41Keyboard Wedge/USB Keyboard — cont.START/ENDSTATE BAR CODEFranceGermanyItalyNorwayPortugalSpainSweden

Page 247 - Product Reference Guide D-13

Interface Related Features3-42 PowerScan® 7000BT SRIKeyboard Wedge/USB Keyboard — cont.START/ENDSTATE BAR CODESwitzerlandJapan 106 KeyHungaryCzechSlov

Page 248 - D-14 PowerScan® 7000BT SRI

Interface FeaturesProduct Reference Guide 3-43Keyboard Wedge/USB Keyboard — cont.START/ENDSTATE BAR CODECroatiaPoland

Page 249 - Product Reference Guide D-15

Interface Related Features3-44 PowerScan® 7000BT SRIKeyboard Wedge/USB Keyboard — cont.Caps Lock StateSpecifies which format the scanner sends charact

Page 250 - D-16 PowerScan® 7000BT SRI

Interface FeaturesProduct Reference Guide 3-45Keyboard Wedge/USB Keyboard — cont.Keyboard SimulationAll PCs check the keyboard status during the power

Page 251 - Key Mappings

vi PowerScan® 7000BT SRI

Page 252 - E-2 PowerScan® 7000BT SRI

Interface Related Features3-46 PowerScan® 7000BT SRIKeyboard Wedge/USB Keyboard — cont.START/ENDSTATE BAR CODEDisableKeyboardSimulationEnableKeyboardS

Page 253 - Product Reference Guide E-3

Interface FeaturesProduct Reference Guide 3-47Keyboard Wedge/USB Keyboard — cont.Wedge Quiet IntervalQuiet Interval is the amount of time to look for

Page 254 - E-4 PowerScan® 7000BT SRI

Interface Related Features3-48 PowerScan® 7000BT SRIKeyboard Wedge/USB Keyboard — cont.Intercharacter DelaySTART/ENDMODE BAR CODEOne-half of the delay

Page 255 - Product Reference Guide E-5

Product Reference Guide 4-1Chapter 4Data EditingData Editing OverviewWhen a bar code is scanned, additional information can be sent to the host comput

Page 256 - E-6 PowerScan® 7000BT SRI

Data Editing4-2 PowerScan® 7000BT SRIPlease Keep In Mind...• Modifying a message string is not a mandatory requirement. Data editing is a sophisticat

Page 257 - Product Reference Guide E-7

Global Prefix/SuffixProduct Reference Guide 4-3Global Prefix/Suffix — continuedExample: Setting a PrefixIn this example, we’ll set a prefix for all sy

Page 258 - E-8 PowerScan® 7000BT SRI

Data Editing4-4 PowerScan® 7000BT SRIGlobal Prefix/Suffix — continuedSTARTMODE BAR CODESets up to 20 characters each from the set of ASCII characters

Page 259 - Product Reference Guide E-9

AIM IDProduct Reference Guide 4-5AIM IDAIM label identifiers (as opposed to custom characters you select your-self as with label identifiers) can be i

Page 260 - E-10 PowerScan® 7000BT SRI

Data Editing4-6 PowerScan® 7000BT SRIAIM ID — continuedSTARTSTATE BAR CODEDisable AIM IDEnable AIM IDEND

Page 261 - Host Commands

Label IDProduct Reference Guide 4-7Label IDA Label ID is a customizable code of up to two ASCII characters (00-FF), used to identify a bar code (symbo

Page 262 - F-2 PowerScan® 7000BT SRI

Product Reference Guide 1-1Chapter 1Getting StartedThe PowerScan® 7000BT SRI Linear Imager uses Bluetooth® wireless technology1 for communications bet

Page 263 - Sample Symbols

Data Editing4-8 PowerScan® 7000BT SRILabel ID — continuedSTARTOPTION BAR CODELabel IDTransmission: DisableLabel IDPosition: Before Bar Code DataLabel

Page 264

Label IDProduct Reference Guide 4-9Label ID — continuedSTARTOPTION BAR CODESet UPC-Aw/C128 AddonLabel IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE:

Page 265 - Indications

Data Editing4-10 PowerScan® 7000BT SRILabel ID — continuedSTARTOPTION BAR CODESet EAN-8w/P5 AddonLabel IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE:

Page 266 - H-2 PowerScan® 7000BT SRI

Label IDProduct Reference Guide 4-11Label ID — continuedSTARTOPTION BAR CODESet GTINLabel IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE:47 Hex (G)Set

Page 267 - LED Indications

Data Editing4-12 PowerScan® 7000BT SRILabel ID — continuedSTARTOPTION BAR CODESet RSS ExpandedLabel IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE:525

Page 268 - Error Codes

Label IDProduct Reference Guide 4-13Label ID — continuedSTARTOPTION BAR CODESetPharmacode 39Label IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE: 41 H

Page 269

Data Editing4-14 PowerScan® 7000BT SRILabel ID — continuedSTARTOPTION BAR CODESetMSI/PlesseyLabel IDCharacter(s)DEFAULT SETTING FOR THIS FEATURE:40 He

Page 270 - H-6 PowerScan® 7000BT SRI

Label IDProduct Reference Guide 4-15Case ConversionThis feature can convert scanned bar code data to either all lower case or all upper case character

Page 271 - ASCII Chart

Data Editing4-16 PowerScan® 7000BT SRICharacter ConversionCharacter conversion is an eight byte configuration item. The eight bytes are 4 character p

Page 272

Label IDProduct Reference Guide 4-17Character Conversion — continuedSTARTMODE BAR CODECharacterConversionDEFAULT SETTING FOR THIS FEATURE:FFFFFFFFFFFF