BM100
BACKUP MODULE
INSTRUCTION MANUAL
Figure 1 General View
1
2
3
4
Backup/Restore button
BM150 Dis
p
la
y
connecto
r
Write Protection Lock
ID-NET™ Baudrate Switch
6
Backup/Restore Indicator LEDs
5
Network Address Switches
7
Network Type Switch
DESCRIPTION
The BM100 Backup Module is an accessory for the CBX series
connection boxes. It provides the following functions:
Backup and Restore
Complete Configuration and Environmental parameter storage for
network and reading devices. Includes write protection.
Network Address Selection
Hardware Address selection for Host network or ID-NET™ Slave
devices (overrides software configuration).
Network Type Selection
Selection of Host network or ID-NET™ Slave type networking
depending on application and installed accessories.
BM150 Accessory Display Connection (CBX500 only)
Connection to flat cable for BM150 Display and Keypad.
NOTE
When using BM100 in a CBX for Backup & Restore
functions, the network Master only recognizes slaves
of its own type (either scanners or imagers). Use the
SC4000 ID-NET Controller for Backup & Restore
functions on networks with both scanners and
imagers (mixed).
821001402 (Rev. B)
Technical Features
Operating Temperature 0° to 50 °C (+32° to 122 °F)
Storage Temperature -20° to 70 °C (-4° to 158 °F)
Humidity max. 90% non condensing
INSTALLATION
CAUTION
Power must be off during this operation.
The BM100 can easily be installed into the CBX100 or CBX500
connection box by aligning it over its corresponding connector and
pushing down until correctly seated. When closed, the plastic support
inside the CBX cover holds the module in place.
Figure 2 – BM100 Mounting
BACKUP AND RESTORE PROCEDURE
The backup and restore functions are valid for any application layout
type (point-to-point, network, etc.) using either CBX100 or CBX500
connection boxes. They can be performed by:
the BM100 button,
the BM150 Menu,
the Genius™ or VisiSet™ Device Menu commands.
If it ever becomes necessary to replace the reading device it can be
quickly configured through the restore procedure.
BM100 always provides complete backup and restore
functions
(Configuration and Environmental parameters) and cannot be
interrupted once started (LED quickly blinking).
For network nodes, the backup module of the ID-NET™ (or
Lonworks) Master saves the configuration of all the reading
devices in the network, Master and all individual Slaves. The
Slaves must be configured with the same network baudrate
as the Master before
performing the Restore procedure.
For single reading device stations, Slaves, or for RS232
Master/Slave networks, the backup module saves the
configuration only of the specific connected reading device.
Backup
Restore
These functions are cyclical
every 3 seconds:
No Action
To perform Backup:
1. Make sure the Write Protection switch is unlocked.
2. Press and hold the Backup & Restore button for approximately 3
seconds. The green Backup LED (B) lights up.
3. Release the button. The green Backup LED (B) blinks slowly.
4. Press the Backup & Restore button again while the LED is
blinking. The green Backup LED (B) blinks quickly indicating the
backup procedure is active. When the LED turns off the
procedure is complete.
5. Set the Write Protection switch to locked.
To perform Restore:
1. Press and hold the Backup & Restore button for approximately 6
seconds. The yellow Restore LED (R) lights up.
2. Release the button. The yellow Restore LED (R) blinks slowly.
3. Press the Backup & Restore button again while the LED is
blinking. The yellow Restore LED (R) blinks quickly indicating the
restore procedure is active. When the LED turns off the procedure
is complete.
To exit without performing Backup or Restore procedures, release the
button while both LEDs are off (No Action), or wait for about 3
seconds (timeout) after the slow blinking LED.
1
5
6
2
3
7
4
Page view 0
1 2

Summary of Contents

Page 1 - BACKUP AND RESTORE PROCEDURE

BM100 BACKUP MODULE INSTRUCTION MANUAL Figure 1 General View 1 2 3 4 Backup/Restore button BM150 Display connectorWrite Protection Lock ID-

Page 2

NETWORK TYPE SELECTION The network type depends on the application layout and installed accessories. Net Type Switch 0 = None (no network present) 1

Comments to this Manuals

No comments